Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
CHROMÝ, A. ŠOPÁK, P. CÍGLER, H.
Originální název
Validated low-cost standardized VICON configuration as a practical approach to estimating the minimal accuracy of a specific setup
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
Motion Capture (MoCap) is rapidly growing in the sports, biomechanics, healthcare, and medicine segments, where accuracy is crucial. Current research studies are concurrently confirming that the accuracy can be determined only for the specific analyzed configuration and thus recommending performing your own accuracy verification on your specific setup. However, it is often hard to perform since it requires significant effort, time, knowledge of statistical data analysis and often equipment and tools that are not commonly available. This paper deals with this by creating a standardized setup with carefully evaluated accuracy, substituting the on-site validation process (in case of using such a setup) or providing the worst-case accuracy (when a more advanced setup is used). The setup is designed to be low-cost, easily reproducible and cover a wide range of applications - thus VICON setup with five VERO v1.3 cameras is used. The accuracy was evaluated using the robotic manipulator EPSON C3, determining that the absolute positioning accuracy of such a standardized setup is 0.65 mm on average (SD = 0.48, with maximal error of 2.47 mm) and rotation accuracy 0.40 degrees (SD = 0.35, with maximal error of 2.0 degrees), which is negligible considering the experimental diameter of 1.4 m and full angular span. The major source of error was specific to particular spatial and rotational positions; other systematic and other random errors were noticeably smaller. If the standardized setup is used and all its requirements are met, a similar accuracy as validated above can be expected without the need to explicitly validate the specific configuration, which is time-consuming and resource-intensive.
Klíčová slova
VICON; Motion capture; Validation; Accuracy assessment; Standardization
Autoři
CHROMÝ, A.; ŠOPÁK, P.; CÍGLER, H.
Vydáno
2. 7. 2025
Nakladatel
NATURE PORTFOLIO
Místo
BERLIN
ISSN
2045-2322
Periodikum
Scientific Reports
Ročník
15
Číslo
23351
Stát
Spojené království Velké Británie a Severního Irska
Strany od
1
Strany do
13
Strany počet
URL
https://www.nature.com/articles/s41598-025-06111-9
Plný text v Digitální knihovně
http://hdl.handle.net/11012/255373
BibTex
@article{BUT198451, author="Adam {Chromý} and Petr {Šopák} and Hynek {Cígler}", title="Validated low-cost standardized VICON configuration as a practical approach to estimating the minimal accuracy of a specific setup", journal="Scientific Reports", year="2025", volume="15", number="23351", pages="1--13", doi="10.1038/s41598-025-06111-9", issn="2045-2322", url="https://www.nature.com/articles/s41598-025-06111-9" }