Detail publikačního výsledku

EXPERIMENTAL INVESTIGATION OF SPRAY COOLING OF HORIZONTALLY AND VERTICALLY ORIENTED SURFACES

CHABIČOVSKÝ, M.; RAUDENSKÝ, M.

Originální název

EXPERIMENTAL INVESTIGATION OF SPRAY COOLING OF HORIZONTALLY AND VERTICALLY ORIENTED SURFACES

Anglický název

EXPERIMENTAL INVESTIGATION OF SPRAY COOLING OF HORIZONTALLY AND VERTICALLY ORIENTED SURFACES

Druh

Stať ve sborníku v databázi WoS či Scopus

Originální abstrakt

The spray cooling of stainless steel plates was studied using different orientations of the cooled surface. A 1.5 mm-thick test plate was moved vertically or horizontally with a velocity of 3 m/s. Experiments were conducted with mist nozzles oriented either vertically with the spray flowing down or horizontally. The water impingement density was between 0.93– 9.68 kg m2 s-1. It was found that the heat transfer coefficient is similar for horizontally and vertically down oriented nozzles within the surface temperature range of 700–900C. The vertically down spray yields a higher heat transfer coefficient for surface temperatures below 300 C. Furthermore, it was observed that the Leidenfrost temperature is slightly higher for vertically down spray for lower water impingement densities. This shift of the Leidenfrost temperature was not observed for higher water impingement densities.

Anglický abstrakt

The spray cooling of stainless steel plates was studied using different orientations of the cooled surface. A 1.5 mm-thick test plate was moved vertically or horizontally with a velocity of 3 m/s. Experiments were conducted with mist nozzles oriented either vertically with the spray flowing down or horizontally. The water impingement density was between 0.93– 9.68 kg m2 s-1. It was found that the heat transfer coefficient is similar for horizontally and vertically down oriented nozzles within the surface temperature range of 700–900C. The vertically down spray yields a higher heat transfer coefficient for surface temperatures below 300 C. Furthermore, it was observed that the Leidenfrost temperature is slightly higher for vertically down spray for lower water impingement densities. This shift of the Leidenfrost temperature was not observed for higher water impingement densities.

Klíčová slova

spray cooling, surface orientation, heat transfer

Klíčová slova v angličtině

spray cooling, surface orientation, heat transfer

Autoři

CHABIČOVSKÝ, M.; RAUDENSKÝ, M.

Rok RIV

2014

Vydáno

15.05.2013

Nakladatel

Tanger, s.r.o.

Místo

Ostrava

ISBN

978-80-87294-41-3

Kniha

Conference proceedings of 22nd Conference on metallurgy and materials

Edice

první

Strany od

198

Strany do

202

Strany počet

6

URL

BibTex

@inproceedings{BUT99721,
  author="Martin {Chabičovský} and Miroslav {Raudenský}",
  title="EXPERIMENTAL INVESTIGATION OF SPRAY COOLING OF HORIZONTALLY AND VERTICALLY ORIENTED SURFACES",
  booktitle="Conference proceedings of 22nd Conference on metallurgy and materials",
  year="2013",
  series="první",
  number="1",
  pages="198--202",
  publisher="Tanger, s.r.o.",
  address="Ostrava",
  isbn="978-80-87294-41-3",
  url="http://www.metal2014.com/files/proceedings/12/reports/1464.pdf"
}