Detail publikačního výsledku

Ageing of Cadmium Telluride Radiation Detectors and its Diagnostics with Low Frequency Noise

ANDREEV, A.; ŠIK, O.; GRMELA, L.; ŠIKULA, J.

Originální název

Ageing of Cadmium Telluride Radiation Detectors and its Diagnostics with Low Frequency Noise

Anglický název

Ageing of Cadmium Telluride Radiation Detectors and its Diagnostics with Low Frequency Noise

Druh

Článek WoS

Originální abstrakt

Samples of CdTe single crystals which are used as radiation detectors were periodically measured during long time interval with different values of an applied voltage. The samples were also periodically exposed during long time periods to high temperatures of 390 K and to rapid changes of temperature from 300 K to 390 K. After 1.5 years of measurements we observed aging of the samples which resulted in deterioration of their transport characteristics. The resistance of the samples increased significantly and current-voltage characteristics were unstable in time. Noise spectroscopy showed that low frequency noise can be used for detection of CdTe samples ageing as its spectral density increases significantly comparing to the 1/f noise of a high quality sample.

Anglický abstrakt

Samples of CdTe single crystals which are used as radiation detectors were periodically measured during long time interval with different values of an applied voltage. The samples were also periodically exposed during long time periods to high temperatures of 390 K and to rapid changes of temperature from 300 K to 390 K. After 1.5 years of measurements we observed aging of the samples which resulted in deterioration of their transport characteristics. The resistance of the samples increased significantly and current-voltage characteristics were unstable in time. Noise spectroscopy showed that low frequency noise can be used for detection of CdTe samples ageing as its spectral density increases significantly comparing to the 1/f noise of a high quality sample.

Klíčová slova

noise spectroscopy, CdTe radiation detectors, ageing process

Klíčová slova v angličtině

noise spectroscopy, CdTe radiation detectors, ageing process

Autoři

ANDREEV, A.; ŠIK, O.; GRMELA, L.; ŠIKULA, J.

Rok RIV

2014

Vydáno

06.09.2013

Nakladatel

Versita

Místo

Warszawa, Poland

ISSN

0860-8229

Periodikum

Metrology and Measurement Systems

Svazek

2013

Číslo

3

Stát

Polská republika

Strany od

385

Strany do

394

Strany počet

10

URL

BibTex

@article{BUT96607,
  author="Alexey {Andreev} and Ondřej {Šik} and Lubomír {Grmela} and Josef {Šikula}",
  title="Ageing of Cadmium Telluride Radiation Detectors and its Diagnostics with Low Frequency Noise",
  journal="Metrology and Measurement Systems",
  year="2013",
  volume="2013",
  number="3",
  pages="385--394",
  doi="10.2478/mms-2013-0033",
  issn="0860-8229",
  url="http://www.degruyter.com/view/j/mms.2013.20.issue-3/mms-2013-0033/mms-2013-0033.xml"
}