Detail publikačního výsledku

The Application of Radiometric Method for Quality Assessment of Linear Accelerator Shielding Structures

HOBST, L.; VÍTEK, L.; ANTON, O.

Originální název

The Application of Radiometric Method for Quality Assessment of Linear Accelerator Shielding Structures

Anglický název

The Application of Radiometric Method for Quality Assessment of Linear Accelerator Shielding Structures

Druh

Stať ve sborníku v databázi WoS či Scopus

Originální abstrakt

The radiometric measurement instruments by which the density of fresh concretemixtures used for the construction of shielding structures can be continously measured have been developet at the Faculty of Civil Engineering, Brno University of Technology

Anglický abstrakt

The radiometric measurement instruments by which the density of fresh concretemixtures used for the construction of shielding structures can be continously measured have been developet at the Faculty of Civil Engineering, Brno University of Technology

Klíčová slova

radiation protection, linear accelerator, radiometric instruments, shielding structures

Klíčová slova v angličtině

radiation protection, linear accelerator, radiometric instruments, shielding structures

Autoři

HOBST, L.; VÍTEK, L.; ANTON, O.

Vydáno

22.10.2007

Místo

AAENDE, Buenos Aires, Argentina

ISBN

978-987-23957-0-4

Kniha

IV. Conferencia Panamericana de END

Strany od

1

Strany do

10

Strany počet

10

BibTex

@inproceedings{BUT28938,
  author="Leonard {Hobst} and Lubomír {Vítek} and Ondřej {Anton}",
  title="The Application of Radiometric Method for Quality Assessment of Linear Accelerator Shielding Structures",
  booktitle="IV. Conferencia Panamericana de END",
  year="2007",
  pages="1--10",
  address="AAENDE, Buenos Aires, Argentina",
  isbn="978-987-23957-0-4"
}