Gradient Coils Temperature Controller in a Gradient System for MR Tomography

BARTUŠEK, K.; DOKOUPIL, Z.; GESCHEIDTOVÁ, E.

Originální název

Gradient Coils Temperature Controller in a Gradient System for MR Tomography

Anglický název

Gradient Coils Temperature Controller in a Gradient System for MR Tomography

Druh

Stať ve sborníku v databázi WoS či Scopus

Originální abstrakt

A simple gradient coils temperature controller for a gradient magnetic field system has been developed. In the application of modern fast magnetic resonance experiments it can maintain the temperature of gradient coils at a value of 21.2?C with a precision of 0.5?C and protect the gradient system against overloading by excessive short-circuit power. When the temperature and the maximum power are exceeded, it will disconnect all gradients and, simultaneously, signal this state to the operator. A gradient system complemented like this has been experimentally verified on a home-built 200 MHz Magnetic Resonance (MR) Tomography system with a 120 mm bore (with room temperature) in the Institute of Scientific Instruments, Academy of Sciences of the Czech Republic.

Anglický abstrakt

A simple gradient coils temperature controller for a gradient magnetic field system has been developed. In the application of modern fast magnetic resonance experiments it can maintain the temperature of gradient coils at a value of 21.2?C with a precision of 0.5?C and protect the gradient system against overloading by excessive short-circuit power. When the temperature and the maximum power are exceeded, it will disconnect all gradients and, simultaneously, signal this state to the operator. A gradient system complemented like this has been experimentally verified on a home-built 200 MHz Magnetic Resonance (MR) Tomography system with a 120 mm bore (with room temperature) in the Institute of Scientific Instruments, Academy of Sciences of the Czech Republic.

Klíčová slova

MR tomograph, coils temperature, preemphasisi filtering, gradient system

Klíčová slova v angličtině

MR tomograph, coils temperature, preemphasisi filtering, gradient system

Autoři

BARTUŠEK, K.; DOKOUPIL, Z.; GESCHEIDTOVÁ, E.

Vydáno

10.09.2007

Nakladatel

Žilinská univerzita

Místo

Žilina

ISBN

978-80-8070-735-4

Kniha

Reasearch in Telecomunication Technology 2007

Strany od

1

Strany do

5

Strany počet

5

Plný text v Digitální knihovně

BibTex

@inproceedings{BUT23330,
  author="Karel {Bartušek} and Zdeněk {Dokoupil} and Eva {Gescheidtová}",
  title="Gradient Coils Temperature Controller in a Gradient System for MR Tomography",
  booktitle="Reasearch in Telecomunication Technology 2007",
  year="2007",
  number="1",
  pages="1--5",
  publisher="Žilinská univerzita",
  address="Žilina",
  isbn="978-80-8070-735-4"
}