Detail publikačního výsledku

Numerical modeling of CO2 capture in a spray tower with aqueous ammonia and full-cone atomizers

BĚLKA, M.; CEJPEK, O.; LÍZAL, F.; MALÝ, M.; JEDELSKÝ, J.

Originální název

Numerical modeling of CO2 capture in a spray tower with aqueous ammonia and full-cone atomizers

Anglický název

Numerical modeling of CO2 capture in a spray tower with aqueous ammonia and full-cone atomizers

Druh

Článek WoS

Originální abstrakt

Chemical absorption in a spray tower using aqueous ammonia is a promising method for CO2 post-combustion capture, a key step in carbon capture and storage (CCS) approaches. However, this process is highly sensitive to atomization and subsequent droplet hydrodynamics. To investigate the impact of spray parameters on column performance, we conducted MATLAB calculations and CFD simulations focusing on droplet hydrodynamics, evaporation, and CO2 absorption. Evaporation was calculated using an infinite conductivity model while absorption was solved using an empirical model. The effect of droplet diameter on droplet entrainment and wall deposition was revealed via the concept of droplet terminal settling velocity and droplet stopping distance. The capture efficiency for optimal parameters determined by MATLAB calculations was 67 %, which was further enhanced to 74 % by adjusting the spray angle or reducing the gas velocity. CFD simulations of the spray column underlined the necessity of two-way coupled simulations as the spray significantly affects the gas flow and causes, among other things, back-mixing behavior. Droplet stopping distances were longer than those in MAT-LAB calculations, with discrepancies increasing alongside the liquid-to-gas ratio. The evaporative effect was minimal, as the gas quickly became saturated.

Anglický abstrakt

Chemical absorption in a spray tower using aqueous ammonia is a promising method for CO2 post-combustion capture, a key step in carbon capture and storage (CCS) approaches. However, this process is highly sensitive to atomization and subsequent droplet hydrodynamics. To investigate the impact of spray parameters on column performance, we conducted MATLAB calculations and CFD simulations focusing on droplet hydrodynamics, evaporation, and CO2 absorption. Evaporation was calculated using an infinite conductivity model while absorption was solved using an empirical model. The effect of droplet diameter on droplet entrainment and wall deposition was revealed via the concept of droplet terminal settling velocity and droplet stopping distance. The capture efficiency for optimal parameters determined by MATLAB calculations was 67 %, which was further enhanced to 74 % by adjusting the spray angle or reducing the gas velocity. CFD simulations of the spray column underlined the necessity of two-way coupled simulations as the spray significantly affects the gas flow and causes, among other things, back-mixing behavior. Droplet stopping distances were longer than those in MAT-LAB calculations, with discrepancies increasing alongside the liquid-to-gas ratio. The evaporative effect was minimal, as the gas quickly became saturated.

Klíčová slova

CFD modeling, CO2 capture, spray column, droplet size

Klíčová slova v angličtině

CFD modeling, CO2 capture, spray column, droplet size

Autoři

BĚLKA, M.; CEJPEK, O.; LÍZAL, F.; MALÝ, M.; JEDELSKÝ, J.

Vydáno

05.08.2025

Periodikum

INTERNATIONAL JOURNAL OF MULTIPHASE FLOW

Svazek

193

Číslo

dec 2025

Stát

Spojené království Velké Británie a Severního Irska

Strany od

1

Strany do

16

Strany počet

16

URL

BibTex

@article{BUT199241,
  author="Miloslav {Bělka} and Ondřej {Cejpek} and František {Lízal} and Milan {Malý} and Jan {Jedelský}",
  title="Numerical modeling of CO2 capture in a spray tower with aqueous ammonia and full-cone atomizers",
  journal="INTERNATIONAL JOURNAL OF MULTIPHASE FLOW",
  year="2025",
  volume="193",
  number="dec 2025",
  pages="1--16",
  doi="10.1016/j.ijmultiphaseflow.2025.105405",
  issn="0301-9322",
  url="https://www.sciencedirect.com/science/article/pii/S0301932225002812?pes=vor&utm_source=clarivate&getft_integrator=clarivate"
}