Detail publikačního výsledku

Impact of External Injection from FLEX Equipment during LOCA in APR1400

ČERNÝ, T.; MIČIAN, P.; KATOVSKÝ, K.; PTÁČEK, M.

Originální název

Impact of External Injection from FLEX Equipment during LOCA in APR1400

Anglický název

Impact of External Injection from FLEX Equipment during LOCA in APR1400

Druh

Stať ve sborníku v databázi WoS či Scopus

Originální abstrakt

During accident scenarios at nuclear power plants, which include the loss of coolant inventory, it is essential to restore the core cooling capability. Normally, this is achieved by Emergency Core Cooling System (ECCS). However, if this system is depleted or not available, one of the means of restoring core cooling is by providing a supply of emergency cooling water from external source directly into Reactor Pressure Vessel (RPV) using The Diverse and Flexible Coping Strategies (FLEX) or so called FLEX equipment. The aim of this article is to find out the impact of external injection on state of core degradation during Loss-Of-Coolant Accident (LOCA) scenario. Another aim of this study is to determine the FLEX deployment time, after which the external injection is no longer able to prevent RPV failure.

Anglický abstrakt

During accident scenarios at nuclear power plants, which include the loss of coolant inventory, it is essential to restore the core cooling capability. Normally, this is achieved by Emergency Core Cooling System (ECCS). However, if this system is depleted or not available, one of the means of restoring core cooling is by providing a supply of emergency cooling water from external source directly into Reactor Pressure Vessel (RPV) using The Diverse and Flexible Coping Strategies (FLEX) or so called FLEX equipment. The aim of this article is to find out the impact of external injection on state of core degradation during Loss-Of-Coolant Accident (LOCA) scenario. Another aim of this study is to determine the FLEX deployment time, after which the external injection is no longer able to prevent RPV failure.

Klíčová slova

LOCA; external injection; FLEX; APR1400; MELCOR

Klíčová slova v angličtině

LOCA; external injection; FLEX; APR1400; MELCOR

Autoři

ČERNÝ, T.; MIČIAN, P.; KATOVSKÝ, K.; PTÁČEK, M.

Rok RIV

2024

Vydáno

28.06.2023

Nakladatel

Institute of Electrical and Electronics Engineers - IEEE

Místo

Piscataway, New Jersey, USA/Brno, Czech Republic

ISBN

979-8-3503-3593-4

Kniha

2023 23rd International Scientific Conference on Electric Power Engineering (EPE)

Edice

1

ISSN

2376-5631

Periodikum

Proceedings of the ... International Scientific Conference on Electric Power Engineering

Svazek

23

Číslo

1

Stát

Spojené státy americké

Strany počet

4

URL

BibTex

@inproceedings{BUT183618,
  author="Tomáš {Černý} and Peter {Mičian} and Karel {Katovský} and Michal {Ptáček}",
  title="Impact of External Injection from FLEX Equipment during LOCA in APR1400",
  booktitle="2023 23rd International Scientific Conference on Electric Power Engineering (EPE)",
  year="2023",
  series="1",
  journal="Proceedings of the ... International Scientific Conference on Electric Power Engineering",
  volume="23",
  number="1",
  pages="4",
  publisher="Institute of Electrical and Electronics Engineers - IEEE",
  address="Piscataway, New Jersey, USA/Brno, Czech Republic",
  doi="10.1109/EPE58302.2023.10149246",
  isbn="979-8-3503-3593-4",
  issn="2376-5623",
  url="https://ieeexplore.ieee.org/document/10149246"
}