Detail publikačního výsledku

VERTICAL DOSIMETRIC MEASUREMENT OF ELECTRIC DISCHARGE INDUCED AT LIGHTNING IMPULSE VOLTAGE GENERATOR

ŠTĚPÁNOVÁ, D.; KRBAL, M.; MIKEŠ, J.; ŠTĚPÁN, V.; PLOC, O.

Originální název

VERTICAL DOSIMETRIC MEASUREMENT OF ELECTRIC DISCHARGE INDUCED AT LIGHTNING IMPULSE VOLTAGE GENERATOR

Anglický název

VERTICAL DOSIMETRIC MEASUREMENT OF ELECTRIC DISCHARGE INDUCED AT LIGHTNING IMPULSE VOLTAGE GENERATOR

Druh

Článek WoS

Originální abstrakt

This paper deals with the measurement of ionising radiation emitted in the vertical field of electric discharge generated between the tip and the grounded plate electrode. The generator set-up was for 400 consecutive negative discharges with voltage amplitude 0.9 MV, waveform shape 1.2/50 mu s, discharge energy 80 kJ and electrodes 1 m apart. Thermoluminescent, passive detectors were used to avoid electromagnetic interference from the discharge. The detectors were placed at the electrodes and three vertical positions 1 m from the discharge axis. This work extends a previous study focused on dosimetry in the plane parallel to the ground. This experiment confirmed the presence of a photon/electron component at the electrode tip and 0.5 m vertical position at a distance of 1 m from the discharge axis. In addition, the presence of neutrons was found for new positions in the vertical axis and the ground electrode.

Anglický abstrakt

This paper deals with the measurement of ionising radiation emitted in the vertical field of electric discharge generated between the tip and the grounded plate electrode. The generator set-up was for 400 consecutive negative discharges with voltage amplitude 0.9 MV, waveform shape 1.2/50 mu s, discharge energy 80 kJ and electrodes 1 m apart. Thermoluminescent, passive detectors were used to avoid electromagnetic interference from the discharge. The detectors were placed at the electrodes and three vertical positions 1 m from the discharge axis. This work extends a previous study focused on dosimetry in the plane parallel to the ground. This experiment confirmed the presence of a photon/electron component at the electrode tip and 0.5 m vertical position at a distance of 1 m from the discharge axis. In addition, the presence of neutrons was found for new positions in the vertical axis and the ground electrode.

Klíčová slova

LI; Impulse Genertor; Dosimetry; Neutron

Klíčová slova v angličtině

LI; Impulse Genertor; Dosimetry; Neutron

Autoři

ŠTĚPÁNOVÁ, D.; KRBAL, M.; MIKEŠ, J.; ŠTĚPÁN, V.; PLOC, O.

Rok RIV

2023

Vydáno

22.08.2022

Nakladatel

OXFORD UNIV PRESS

Místo

OXFORD

ISSN

1742-3406

Periodikum

RADIATION PROTECTION DOSIMETRY

Svazek

198

Číslo

9-11

Stát

Spojené království Velké Británie a Severního Irska

Strany od

617

Strany do

622

Strany počet

6

URL

BibTex

@article{BUT179938,
  author="Dagmar {Štěpánová} and Michal {Krbal} and Jan {Mikeš} and Václav {Štěpán} and Ondřej {Ploc}",
  title="VERTICAL DOSIMETRIC MEASUREMENT OF ELECTRIC DISCHARGE INDUCED AT LIGHTNING IMPULSE VOLTAGE GENERATOR",
  journal="RADIATION PROTECTION DOSIMETRY",
  year="2022",
  volume="198",
  number="9-11",
  pages="617--622",
  doi="10.1093/rpd/ncac107",
  issn="0144-8420",
  url="https://academic.oup.com/rpd/article-abstract/198/9-11/617/6673008?redirectedFrom=fulltext"
}