Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikačního výsledku
SUK, L.; PETROSYAN, T.; ŠTEVANKA, K.; KATOVSKÝ, K.
Originální název
Validation of Results of Brno CHF Experimental Loop in Annular Channel
Anglický název
Druh
Stať ve sborníku v databázi WoS či Scopus
Originální abstrakt
This study presents an experimental investigation of critical heat flux on Inconel 625 and compares the results with experimental work as well as correlations from literature. Tests were performed on the loop at pressure up to 0.4 MPa and mass flow rate up to 0.4 kg/s. The heated tube was 380 mm long with an outside and inside diameter of 9.1 mm and 8~mm respectively. The boiling crisis was achieved using DC heating and the temperature of test section was measured using K-type thermocouples. Finally, recorded values were compared to and validated with the analytical correlations from scientific literature and other experimental results.
Anglický abstrakt
Klíčová slova
CHF; Critical Heat Flux; Inconel; heat transfer
Klíčová slova v angličtině
Autoři
Rok RIV
2021
Vydáno
19.10.2020
ISBN
978-1-7281-9479-0
Kniha
Proccedings of the 2020 21th International Scientific Conference on Electric Power Engineering (EPE)
Edice
1
Strany od
293
Strany do
298
Strany počet
6
BibTex
@inproceedings{BUT164775, author="Ladislav {Suk} and Taron {Petrosyan} and Kamil {Števanka} and Karel {Katovský}", title="Validation of Results of Brno CHF Experimental Loop in Annular Channel", booktitle="Proccedings of the 2020 21th International Scientific Conference on Electric Power Engineering (EPE)", year="2020", series="1", number="1", pages="293--298", isbn="978-1-7281-9479-0" }