Detail publikačního výsledku

Assessment of the resistance of ventilated facade system by vacuum testing

SCHMID, P.; DANĚK, P.; ROZSYPALOVÁ, I.; HOLOMEK, J.; JURÁNEK, P.

Originální název

Assessment of the resistance of ventilated facade system by vacuum testing

Anglický název

Assessment of the resistance of ventilated facade system by vacuum testing

Druh

Stať ve sborníku v databázi WoS či Scopus

Originální abstrakt

The aim of this research was to determine experimentally the mechanical resistance of preset ventilated facade systems exposed to wind suction. In accordance with the European ETAG 034 Guideline, Part 1, seven facade assemblies were tested. The wind suction load was simulated in a vacuum test in the AdMaS centre using the universal vacuum loading system. The test was performed with a load increasing in increments, where after each level, the specimens were unloaded. The effect of the density of connections of load-bearing plates with the structure of subframes was demonstrated. Further, the resistance to wind suction of specimens with timber subframe was slightly higher than that of specimens with aluminium subframe.

Anglický abstrakt

The aim of this research was to determine experimentally the mechanical resistance of preset ventilated facade systems exposed to wind suction. In accordance with the European ETAG 034 Guideline, Part 1, seven facade assemblies were tested. The wind suction load was simulated in a vacuum test in the AdMaS centre using the universal vacuum loading system. The test was performed with a load increasing in increments, where after each level, the specimens were unloaded. The effect of the density of connections of load-bearing plates with the structure of subframes was demonstrated. Further, the resistance to wind suction of specimens with timber subframe was slightly higher than that of specimens with aluminium subframe.

Klíčová slova

Assessment of the resistance, ventilated facade system, vacuum testing

Klíčová slova v angličtině

Assessment of the resistance, ventilated facade system, vacuum testing

Autoři

SCHMID, P.; DANĚK, P.; ROZSYPALOVÁ, I.; HOLOMEK, J.; JURÁNEK, P.

Rok RIV

2020

Vydáno

29.05.2019

Nakladatel

IOP Publishing

Místo

Bristol

Kniha

IOP Conference Series: Materials Science and Engineering

ISSN

1757-8981

Periodikum

IOP Conference Series: Materials Science and Engineering

Svazek

549

Číslo

1

Stát

Spojené království Velké Británie a Severního Irska

Strany od

1

Strany do

6

Strany počet

6

URL

BibTex

@inproceedings{BUT157341,
  author="Pavel {Schmid} and Petr {Daněk} and Iva {Čairović} and Josef {Holomek} and Pavel {Juránek}",
  title="Assessment of the resistance of ventilated facade system by vacuum testing",
  booktitle="IOP Conference Series: Materials Science and Engineering",
  year="2019",
  journal="IOP Conference Series: Materials Science and Engineering",
  volume="549",
  number="1",
  pages="1--6",
  publisher="IOP Publishing",
  address="Bristol",
  doi="10.1088/1757-899X/549/1/012034",
  issn="1757-8981",
  url="https://iopscience.iop.org/article/10.1088/1757-899X/549/1/012034/pdf"
}

Dokumenty