Detail publikačního výsledku

Computed tomography based procedure for reproducible porosity measurement of additive manufactured samples

ZIKMUND, T.; ŠALPLACHTA, J.; ZATOČILOVÁ, A.; BŘÍNEK, A.; PANTĚLEJEV, L.; ŠTĚPÁNEK, R.; KOUTNÝ, D.; PALOUŠEK, D.; KAISER, J.

Originální název

Computed tomography based procedure for reproducible porosity measurement of additive manufactured samples

Anglický název

Computed tomography based procedure for reproducible porosity measurement of additive manufactured samples

Druh

Článek WoS

Originální abstrakt

Metallic parts made by selective laser melting technology are evaluated for internal porosity. The non-standardized pores segmentation is one of the key aspects to apply in order to achieve a precise porosity measurement using X-ray computed micro tomography. In this work, we present a new porosity analysis procedure which is based on the global thresholding and the correlation with metallographic image data. The procedure is independent on the obtained voxel resolution and makes an analysis reproducible. The novelty of this work is that the computed tomography is used for a comparative porosity analysis of samples from separate measurements. The functionality of proposed procedure is demonstrated on a test sample of aluminium alloy and is compared to standardly used procedures

Anglický abstrakt

Metallic parts made by selective laser melting technology are evaluated for internal porosity. The non-standardized pores segmentation is one of the key aspects to apply in order to achieve a precise porosity measurement using X-ray computed micro tomography. In this work, we present a new porosity analysis procedure which is based on the global thresholding and the correlation with metallographic image data. The procedure is independent on the obtained voxel resolution and makes an analysis reproducible. The novelty of this work is that the computed tomography is used for a comparative porosity analysis of samples from separate measurements. The functionality of proposed procedure is demonstrated on a test sample of aluminium alloy and is compared to standardly used procedures

Klíčová slova

Porosity measurement, SLM sample, Metallography, Micro tomography, Automatic pores segmentation

Klíčová slova v angličtině

Porosity measurement, SLM sample, Metallography, Micro tomography, Automatic pores segmentation

Autoři

ZIKMUND, T.; ŠALPLACHTA, J.; ZATOČILOVÁ, A.; BŘÍNEK, A.; PANTĚLEJEV, L.; ŠTĚPÁNEK, R.; KOUTNÝ, D.; PALOUŠEK, D.; KAISER, J.

Rok RIV

2020

Vydáno

01.04.2019

ISSN

1879-1174

Periodikum

NDT & E INTERNATIONAL

Svazek

103

Číslo

1

Stát

Spojené království Velké Británie a Severního Irska

Strany od

111

Strany do

118

Strany počet

8

URL

Plný text v Digitální knihovně

BibTex

@article{BUT156952,
  author="Tomáš {Zikmund} and Jakub {Šalplachta} and Aneta {Zatočilová} and Adam {Břínek} and Libor {Pantělejev} and Roman {Štěpánek} and Daniel {Koutný} and David {Paloušek} and Jozef {Kaiser}",
  title="Computed tomography based procedure for reproducible porosity measurement of additive manufactured samples",
  journal="NDT & E INTERNATIONAL",
  year="2019",
  volume="103",
  number="1",
  pages="111--118",
  doi="10.1016/j.ndteint.2019.02.008",
  issn="0963-8695",
  url="https://www.sciencedirect.com/science/article/pii/S0963869518303700"
}