Building Performance Simulation of Industrial Hall with Excessive Heat Loads

WEYR, J.; ŠIKULA, O.; HIRŠ, J.

Originální název

Building Performance Simulation of Industrial Hall with Excessive Heat Loads

Anglický název

Building Performance Simulation of Industrial Hall with Excessive Heat Loads

Druh

Článek Scopus

Originální abstrakt

Numerical simulations are becoming an integral part of the design procedure of buildings, building systems and technologies allowing for not only evaluating the building energy demands and indoor quality but also for studying the influence of various design parameters and aspects of a building’s internal microclimate. In this case study, a numerical simulation of an internal microclimate in an industrial building in the simulation software BSim 2002 was performed in order to assess the internal microclimate, examine the effect of precooling and determine the required cooling capacity. Furthermore, this article deals with the analysis of the influence of excessive internal gains caused by bogie-hearth chamber furnaces and their implementation into the simulation software. The results illustrate the minor effect of precooling for this case study and the insufficiency of the cooling ca pacity in the investiga ted industrial object.

Anglický abstrakt

Numerical simulations are becoming an integral part of the design procedure of buildings, building systems and technologies allowing for not only evaluating the building energy demands and indoor quality but also for studying the influence of various design parameters and aspects of a building’s internal microclimate. In this case study, a numerical simulation of an internal microclimate in an industrial building in the simulation software BSim 2002 was performed in order to assess the internal microclimate, examine the effect of precooling and determine the required cooling capacity. Furthermore, this article deals with the analysis of the influence of excessive internal gains caused by bogie-hearth chamber furnaces and their implementation into the simulation software. The results illustrate the minor effect of precooling for this case study and the insufficiency of the cooling ca pacity in the investiga ted industrial object.

Klíčová slova

transient simulation; BSim; Industrial building; Internal microclimate; Chamber furnaces

Klíčová slova v angličtině

transient simulation; BSim; Industrial building; Internal microclimate; Chamber furnaces

Autoři

WEYR, J.; ŠIKULA, O.; HIRŠ, J.

Rok RIV

2019

Vydáno

10.01.2019

Nakladatel

Society of Environmental Engineering

Místo

Prague

ISSN

1210-1389

Periodikum

Vytápění, větrání, instalace

Svazek

27

Číslo

6

Stát

Česká republika

Strany od

344

Strany do

347

Strany počet

4

URL

BibTex

@article{BUT153217,
  author="Jan {Weyr} and Ondřej {Šikula} and Jiří {Hirš}",
  title="Building Performance Simulation of Industrial Hall with Excessive Heat Loads",
  journal="Vytápění, větrání, instalace",
  year="2019",
  volume="27",
  number="6",
  pages="344--347",
  issn="1210-1389",
  url="http://www.stpcr.cz/?download=_/special/vvi_6_2018.pdf"
}