Detail publikačního výsledku

Temperature Changes of Lead Acid Battery Cell with Pulse Charging in a Flooded State

KŘIVÍK, P.

Originální název

Temperature Changes of Lead Acid Battery Cell with Pulse Charging in a Flooded State

Anglický název

Temperature Changes of Lead Acid Battery Cell with Pulse Charging in a Flooded State

Druh

Článek WoS

Originální abstrakt

The paper describes temperature changes of lead acid battery cell in the course of discharging and pulse charging in a flooded construction. There was found effect of different pulse charging with and without depolarization pulse on increase of cell temperature compared with constant current charging mode.

Anglický abstrakt

The paper describes temperature changes of lead acid battery cell in the course of discharging and pulse charging in a flooded construction. There was found effect of different pulse charging with and without depolarization pulse on increase of cell temperature compared with constant current charging mode.

Klíčová slova

Lead acid battery, Pulse charging, Temperature

Klíčová slova v angličtině

Lead acid battery, Pulse charging, Temperature

Autoři

KŘIVÍK, P.

Rok RIV

2017

Vydáno

23.12.2016

Nakladatel

ECS

ISSN

1938-6737

Periodikum

ECS Transaction

Svazek

74

Číslo

1

Stát

Spojené státy americké

Strany od

123

Strany do

130

Strany počet

8

BibTex

@article{BUT129758,
  author="Petr {Křivík}",
  title="Temperature Changes of Lead Acid Battery Cell with Pulse Charging in a Flooded State",
  journal="ECS Transaction",
  year="2016",
  volume="74",
  number="1",
  pages="123--130",
  doi="10.1149/07401.0123ecst",
  issn="1938-6737"
}

Dokumenty