Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikačního výsledku
DRÁPELA, J.; KRÁTKÝ, M.; WEIDINGER, L.; ZÁVODNÝ, M.
Originální název
Light Flicker of Fluorescent Lamps with Different Types of Ballasts Caused by Interharmonics
Anglický název
Druh
Stať ve sborníku v databázi WoS či Scopus
Originální abstrakt
The paper presents an analysis of the voltage fluctuations caused by interharmonics and its influence on luminous flux fluctuations of used combinations of fluorescent lamps and ballasts. One of the analysis results is a concept determining light sources sensitivity to such disturbing type based on frequency components utilization. Further a complex measured data file of sensitivity curves in various combinations of fluorescent lamps and ballasts are pointed. Measured and compared combinations include various types of fluorescent lamps, various wattages, modes of operation of the ballast and its specific designs and dimensioning of circuit elements etc.
Anglický abstrakt
Klíčová slova
Ballast Types, Flicker Curve, Gain Factor, Interharmonics, Light Flicker, Voltage Fluctuation
Klíčová slova v angličtině
Autoři
Rok RIV
2010
Vydáno
27.06.2005
Nakladatel
IEEE PES
Místo
St. Petersburg
ISBN
978-5-93208-034-4
Kniha
IEEE PowerTech 2005 Conference Proceedings
Strany od
1
Strany do
7
Strany počet
URL
http://www.sei.irk.ru/PowerTech2005/abstr.html
BibTex
@inproceedings{BUT12658, author="Jiří {Drápela} and Milan {Krátký} and Libor {Weidinger} and Michal {Závodný}", title="Light Flicker of Fluorescent Lamps with Different Types of Ballasts Caused by Interharmonics", booktitle="IEEE PowerTech 2005 Conference Proceedings", year="2005", number="1", pages="1--7", publisher="IEEE PES", address="St. Petersburg", isbn="978-5-93208-034-4", url="http://www.sei.irk.ru/PowerTech2005/abstr.html" }