Originální abstrakt

The paper introduces the results of research study aimed at sealing possibilities of cement-based substrates. The intention of the presented research is to verify whether the permanent and reliable seal in materials can be implemented even without additional surface treatment. The task is approached experimentally, using test procedures based on relevant European technical standards. The tested substrate is made up of glass-fiber reinforced concrete facade elements intended for the final cladding of buildings without any further surface treatment. The selected substrate is 13 mm thick, one test sample consist of two identical pieces of substrate connected by chosen sealant. A group of ten industrially-produced, commonly available sealants by three manufacturers is included in the experimental measurements. The research brought an answer to the question of the sealing possibilities of an unprocessed structures and also solved the issue of the most suitable type of sealant meant for this purpose.

Anglický abstrakt

The paper introduces the results of research study aimed at sealing possibilities of cement-based substrates. The intention of the presented research is to verify whether the permanent and reliable seal in materials can be implemented even without additional surface treatment. The task is approached experimentally, using test procedures based on relevant European technical standards. The tested substrate is made up of glass-fiber reinforced concrete facade elements intended for the final cladding of buildings without any further surface treatment. The selected substrate is 13 mm thick, one test sample consist of two identical pieces of substrate connected by chosen sealant. A group of ten industrially-produced, commonly available sealants by three manufacturers is included in the experimental measurements. The research brought an answer to the question of the sealing possibilities of an unprocessed structures and also solved the issue of the most suitable type of sealant meant for this purpose.

Klíčová slova

Adhesive Failure, Cohesive Failure, Extension, Glass-fibre reinforced concrete, Maintained Extension, Seal, Sealant

Klíčová slova v angličtině

Adhesive Failure, Cohesive Failure, Extension, Glass-fibre reinforced concrete, Maintained Extension, Seal, Sealant

Autoři

ŠLANHOF, J.; NEČASOVÁ, B.; LIŠKA, P.; ŠIMÁČKOVÁ, M.

Rok RIV

2017

Vydáno

28.01.2016

Nakladatel

Trans Tech Publications

Místo

Switzerland

ISBN

978-80-227-4469-0

Kniha

enviBUILD 2015

ISSN

1660-9336

Periodikum

Applied Mechanics and Materials

Svazek

824

Číslo

1

Stát

Švýcarská konfederace

Strany od

164

Strany do

171

Strany počet

8

BibTex

@inproceedings{BUT119731,
  author="Jiří {Šlanhof} and Barbora {Nečasová} and Pavel {Liška} and Martina {Hanzelková}",
  title="Verification of Sealing Possibilities of Cement – Based Structures without Additional Surface Treatment",
  booktitle="enviBUILD 2015",
  year="2016",
  journal="Applied Mechanics and Materials",
  volume="824",
  number="1",
  pages="164--171",
  publisher="Trans Tech Publications",
  address="Switzerland",
  doi="10.4028/www.scientific.net/AMM.824.164",
  isbn="978-80-227-4469-0",
  issn="1660-9336"
}