Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikačního výsledku
KRATOCHVÍLA, J.; JIŘÍK, R.; BARTOŠ, M.; STANDARA, M.; STARČUK, Z.; TAXT, T.
Originální název
Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI
Anglický název
Druh
Článek WoS
Originální abstrakt
Purpose One of the main challenges in quantitative dynamic contrast-enhanced (DCE) MRI is estimation of the arterial input function (AIF). Usually, the signal from a single artery (ignoring contrast dispersion, partial volume effects and flow artifacts) or a population average of such signals (also ignoring variability between patients) is used. Methods Multi-channel blind deconvolution is an alternative approach avoiding most of these problems. The AIF is estimated directly from the measured tracer concentration curves in several tissues. This contribution extends the published methods of multi-channel blind deconvolution by applying a more realistic model of the impulse residue function, the distributed capillary adiabatic tissue homogeneity model (DCATH). In addition, an alternative AIF model is used and several AIF-scaling methods are tested. Results The proposed method is evaluated on synthetic data with respect to the number of tissue regions and to the signal-to-noise ratio. Evaluation on clinical data (renal cell carcinoma patients before and after the beginning of the treatment) gave consistent results. An initial evaluation on clinical data indicates more reliable and less noise sensitive perfusion parameter estimates. Conclusion Blind multi-channel deconvolution using the DCATH model might be a method of choice for AIF estimation in a clinical setup. Magn Reson Med, 2015. © 2015 Wiley Periodicals, Inc.
Anglický abstrakt
Klíčová slova
dynamic contrast-enhanced magnetic resonance imaging;multi-channel blind deconvolution;arterial input function;impulse residue function;renal cell carcinoma
Klíčová slova v angličtině
Autoři
Rok RIV
2016
Vydáno
13.04.2015
Nakladatel
John Wiley & Sons, Inc.
ISSN
0740-3194
Periodikum
Magnetic Resonance in Medicine
Svazek
-
Číslo
Stát
Spojené státy americké
Strany od
1
Strany do
11
Strany počet
URL
http://onlinelibrary.wiley.com/doi/10.1002/mrm.25619/epdf
BibTex
@article{BUT115759, author="Jiří {Kratochvíla} and Radovan {Jiřík} and Michal {Bartoš} and Michal {Standara} and Zenon {Starčuk} and Torfinn {Taxt}", title="Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI", journal="Magnetic Resonance in Medicine", year="2015", volume="-", number="-", pages="1--11", doi="10.1002/mrm.25619", issn="0740-3194", url="http://onlinelibrary.wiley.com/doi/10.1002/mrm.25619/epdf" }