Detail publikačního výsledku

Thermal degradation of high molar mass hyaluronan in solution and in powder; comparison with BSA

MONDEK, J.; KALINA, M.; SIMULESCU, V.; PEKAŘ, M.

Originální název

Thermal degradation of high molar mass hyaluronan in solution and in powder; comparison with BSA

Anglický název

Thermal degradation of high molar mass hyaluronan in solution and in powder; comparison with BSA

Druh

Článek WoS

Originální abstrakt

The aim of the present work was to compare the thermal degradation of bovine serum albumin and hyaluronic acid of different molar masses by determining the loss in molecular weight by means of SEC-MALLS.

Anglický abstrakt

The aim of the present work was to compare the thermal degradation of bovine serum albumin and hyaluronic acid of different molar masses by determining the loss in molecular weight by means of SEC-MALLS.

Klíčová slova

Bovine serum albumin, Hyaluronic acid, Thermal degradation, SEC-MALLS, Electrophoretic light scattering

Klíčová slova v angličtině

Bovine serum albumin, Hyaluronic acid, Thermal degradation, SEC-MALLS, Electrophoretic light scattering

Autoři

MONDEK, J.; KALINA, M.; SIMULESCU, V.; PEKAŘ, M.

Rok RIV

2016

Vydáno

18.06.2015

ISSN

0141-3910

Periodikum

POLYMER DEGRADATION AND STABILITY

Svazek

120

Číslo

1

Stát

Spojené království Velké Británie a Severního Irska

Strany od

107

Strany do

113

Strany počet

7

BibTex

@article{BUT115171,
  author="Jakub {Mondek} and Michal {Kalina} and Vasile {Simulescu} and Miloslav {Pekař}",
  title="Thermal degradation of high molar mass hyaluronan in solution and in powder; comparison with BSA",
  journal="POLYMER DEGRADATION AND STABILITY",
  year="2015",
  volume="120",
  number="1",
  pages="107--113",
  doi="10.1016/j.polymdegradstab.2015.06.012",
  issn="0141-3910"
}