Detail publikačního výsledku

Absolute ultrasound perfusion parameter quantification of a tissue-mimicking phantom using bolus tracking

MÉZL, M.; JIŘÍK, R.; HARABIŠ, V.; KOLÁŘ, R.; STANDARA, M.; NYLUND, K.; GILJA, O.; TAXT, T.

Originální název

Absolute ultrasound perfusion parameter quantification of a tissue-mimicking phantom using bolus tracking

Anglický název

Absolute ultrasound perfusion parameter quantification of a tissue-mimicking phantom using bolus tracking

Druh

Článek WoS

Originální abstrakt

This study presents three methods for absolute quantification in ultrasound perfusion analysis based on bolus tracking. The first two methods deconvolve the perfusion time sequence with a measured AIF, using a nonparametric or a parametric model of the tissue residue function, respectively. The third method is a simplified approach avoiding deconvolution by assuming a narrow AIF. A phantom with a dialyzer filter as a tissue-mimicking model was used for evaluation. Estimated mean transit times and blood volumes were compared with the theoretical values. A match with a maximum error of 12% was achieved.

Anglický abstrakt

This study presents three methods for absolute quantification in ultrasound perfusion analysis based on bolus tracking. The first two methods deconvolve the perfusion time sequence with a measured AIF, using a nonparametric or a parametric model of the tissue residue function, respectively. The third method is a simplified approach avoiding deconvolution by assuming a narrow AIF. A phantom with a dialyzer filter as a tissue-mimicking model was used for evaluation. Estimated mean transit times and blood volumes were compared with the theoretical values. A match with a maximum error of 12% was achieved.

Klíčová slova

ultrasound perfusion analysis, ultrasound contrast agent, absolute quantification, phantom model

Klíčová slova v angličtině

ultrasound perfusion analysis, ultrasound contrast agent, absolute quantification, phantom model

Autoři

MÉZL, M.; JIŘÍK, R.; HARABIŠ, V.; KOLÁŘ, R.; STANDARA, M.; NYLUND, K.; GILJA, O.; TAXT, T.

Rok RIV

2016

Vydáno

11.05.2015

Nakladatel

IEEE

ISSN

0885-3010

Periodikum

IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL

Svazek

62

Číslo

5

Stát

Spojené státy americké

Strany od

983

Strany do

987

Strany počet

5

Plný text v Digitální knihovně

BibTex

@article{BUT114552,
  author="Martin {Mézl} and Radovan {Jiřík} and Vratislav {Harabiš} and Radim {Kolář} and Michal {Standara} and Kim {Nylund} and Odd Helge {Gilja} and Torfinn {Taxt}",
  title="Absolute ultrasound perfusion parameter quantification of a tissue-mimicking phantom using bolus tracking",
  journal="IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL",
  year="2015",
  volume="62",
  number="5",
  pages="983--987",
  doi="10.1109/TUFFC.2014.006896",
  issn="0885-3010"
}