Detail publikačního výsledku

Effect of matte coating on 3D optical measurement accuracy

PALOUŠEK, D.; OMASTA, M.; KOUTNÝ, D.; BEDNÁŘ, J.; DOKOUPIL, F.; KOUTECKÝ, T.

Originální název

Effect of matte coating on 3D optical measurement accuracy

Anglický název

Effect of matte coating on 3D optical measurement accuracy

Druh

Článek WoS

Originální abstrakt

The aim of this study is to gain basic information about matte coating thickness in the area of 3D optical digitization. Thickness measurement was performed for two matting materials; chalk spray and titanium coating. A 3D optical scanner ATOS III, Triple Scan was used for data capturing and evaluation. The scanner technology is based on active fringe projection and triangulation. Fifteen measurements for chalk material and fifteen for titanium coating were carried out. The measurement conditions included the effects of lighting, operation, imperfections of coating materials deposition, etc. The results show significant differences between chalk and titanium matting materials.

Anglický abstrakt

The aim of this study is to gain basic information about matte coating thickness in the area of 3D optical digitization. Thickness measurement was performed for two matting materials; chalk spray and titanium coating. A 3D optical scanner ATOS III, Triple Scan was used for data capturing and evaluation. The scanner technology is based on active fringe projection and triangulation. Fifteen measurements for chalk material and fifteen for titanium coating were carried out. The measurement conditions included the effects of lighting, operation, imperfections of coating materials deposition, etc. The results show significant differences between chalk and titanium matting materials.

Klíčová slova

3D optical digitizing, matte coating, thickness of matting layer, active fringe projection

Klíčová slova v angličtině

3D optical digitizing, matte coating, thickness of matting layer, active fringe projection

Autoři

PALOUŠEK, D.; OMASTA, M.; KOUTNÝ, D.; BEDNÁŘ, J.; DOKOUPIL, F.; KOUTECKÝ, T.

Rok RIV

2016

Vydáno

06.01.2015

Nakladatel

Elsevier

ISSN

0925-3467

Periodikum

OPTICAL MATERIALS

Svazek

40

Číslo

1

Stát

Nizozemsko

Strany od

1

Strany do

9

Strany počet

9

BibTex

@article{BUT110898,
  author="David {Paloušek} and Milan {Omasta} and Daniel {Koutný} and Josef {Bednář} and Filip {Dokoupil} and Tomáš {Koutecký}",
  title="Effect of matte coating on 3D optical measurement accuracy",
  journal="OPTICAL MATERIALS",
  year="2015",
  volume="40",
  number="1",
  pages="1--9",
  doi="10.1016/j.optmat.2014.11.020",
  issn="0925-3467"
}