Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikačního výsledku
MLÝNEK, P.; KOUTNÝ, M.; MIŠUREC, J.; FUJDIAK, R.
Originální název
Evaluation of Load Impedances, Discontinuity and Impedance Mismatch in PLC Networks by Experimental Measurements with Coupling Circuits
Anglický název
Druh
Stať ve sborníku v databázi WoS či Scopus
Originální abstrakt
Two different coupling circuits, capacitive and inductive, are introduced. These coupling circuits are analyzed by laboratory measurements. The measurements of the load impedance of coupling circuits are realized. The general discontinuity in communication path is presented in form of coupling circuit. The influence of position of coupling circuit and number of branches on transfer function is also demonstrated. In addition, the simple model of coupling circuit was designed and the effect of discontinuity and impedance mismatch will be shown on the multipath model.
Anglický abstrakt
Klíčová slova
Power line communication, coupling circuit, transfer function, measurement, load impedance, discontinuity
Klíčová slova v angličtině
Autoři
Rok RIV
2015
Vydáno
09.07.2015
Místo
Berlin, Germany
ISBN
978-1-4799-8497-8
Kniha
Proceedings of the 38th International Conference on Telecommunication and Signal Processing
Strany od
657
Strany do
661
Strany počet
5
URL
https://ieeexplore.ieee.org/document/7296345
BibTex
@inproceedings{BUT110174, author="Petr {Mlýnek} and Martin {Koutný} and Jiří {Mišurec} and Radek {Fujdiak}", title="Evaluation of Load Impedances, Discontinuity and Impedance Mismatch in PLC Networks by Experimental Measurements with Coupling Circuits", booktitle="Proceedings of the 38th International Conference on Telecommunication and Signal Processing", year="2015", pages="657--661", address="Berlin, Germany", doi="10.1109/TSP.2015.7296345", isbn="978-1-4799-8497-8", url="https://ieeexplore.ieee.org/document/7296345" }