Detail publikace
The Corrosion Status of Reinforced Concrete Structure Monitoring by Impact-echo method
CHOBOLA, Z. ŠAMÁRKOVÁ, K. ŠTEFKOVÁ, D.
Originální název
The Corrosion Status of Reinforced Concrete Structure Monitoring by Impact-echo method
Anglický název
The Corrosion Status of Reinforced Concrete Structure Monitoring by Impact-echo method
Jazyk
en
Originální abstrakt
The paper deals with the study of dominant frequencies of an Impact-Echo method response signal obtained from a reinforced concrete beam with a steel rod diameter of 8 mm. Tension pulse was produced in axis of the rod at one end and detected in axis at opposite end of rod. Dominant frequencies of the response signal will be the main criterions for the reinforced concrete rebar corrosion progress. The article presents the results of measurements obtained after 12 months controlled degradation in aqueous NaCl solution. The results were compared with measurements of electrical resistance of reinforcing steel by using the Thomson double bridge.
Anglický abstrakt
The paper deals with the study of dominant frequencies of an Impact-Echo method response signal obtained from a reinforced concrete beam with a steel rod diameter of 8 mm. Tension pulse was produced in axis of the rod at one end and detected in axis at opposite end of rod. Dominant frequencies of the response signal will be the main criterions for the reinforced concrete rebar corrosion progress. The article presents the results of measurements obtained after 12 months controlled degradation in aqueous NaCl solution. The results were compared with measurements of electrical resistance of reinforcing steel by using the Thomson double bridge.
Dokumenty
BibTex
@inproceedings{BUT104957,
author="Zdeněk {Chobola} and Kristýna {Timčaková} and Daniela {Kysilková}",
title="The Corrosion Status of Reinforced Concrete Structure Monitoring by Impact-echo method",
annote="The paper deals with the study of dominant frequencies of an Impact-Echo method response signal obtained from a reinforced concrete beam with a steel rod diameter of 8 mm. Tension pulse was produced in axis of the rod at one end and detected in axis at opposite end of rod. Dominant frequencies of the response signal will be the main criterions for the reinforced concrete rebar corrosion progress. The article presents the results of measurements obtained after 12 months controlled degradation in aqueous NaCl solution. The results were compared with measurements of electrical resistance of reinforcing steel by using the Thomson double bridge.",
address="Trans Tech Publications",
booktitle="International Conference on Advanced Material and Manufacturing Science, ICAMMS 2012",
chapter="104957",
doi="10.4028/www.scientific.net/AMR.875-877.445",
howpublished="online",
institution="Trans Tech Publications",
number="1",
year="2014",
month="january",
pages="445--449",
publisher="Trans Tech Publications",
type="conference paper"
}