Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikačního výsledku
JAN, J.
Originální název
Deriving attenuation profiles from raw digital ultrasonographic data
Anglický název
Druh
Článek recenzovaný mimo WoS a Scopus
Originální abstrakt
The objective of the paper is to estimate automatically one-dimensional attenuation profiles on isolated “rays”, forming ultrasonic images. The estimates are entirely based on raw digital ultrasonographic data, without reference to any a-priori knowledge on the tissue character. Using a common model of ultrasound propagation in homogeneous media, the presented “layered” formulation allowed for simplified, thus manageable, estimation of the attenuation profiles. The derived model has been discretised and the least squares method used for computing vectors of unknown coefficients of attenuation and dispersion. The results of analysing real ultrasonographic data, as presented on included figures, are rather promising, in spite of the mentioned simplifications.
Anglický abstrakt
Klíčová slova v angličtině
ultrasonography, image processing, raw ultrasound data, attenuation map, ultrasound attenuation estimation
Autoři
Vydáno
31.03.2002
ISSN
0013-578X
Periodikum
Journal of Electrical Engineering
Svazek
2002
Číslo
3-4
Stát
Slovenská republika
Strany od
70
Strany počet
6
BibTex