Detail publikačního výsledku

Rapid prediction of maximal temperature in liquid-cooled li-ion battery modules: a case study using polymeric hollow fiber cooling channels

HVOŽĎA, J.; BOHÁČEK, J.; BARTULI, E.; MRÁZ, K.; VAKHRUSHEV, A.; KARIMI-SIBAKI, E.; RAUDENSKÝ, M.

Originální název

Rapid prediction of maximal temperature in liquid-cooled li-ion battery modules: a case study using polymeric hollow fiber cooling channels

Anglický název

Rapid prediction of maximal temperature in liquid-cooled li-ion battery modules: a case study using polymeric hollow fiber cooling channels

Druh

Článek WoS

Originální abstrakt

The growing demand for high-performance electric vehicles has highlighted the need for efficient thermal management of Li-Ion batteries. These systems are typically based on liquidcooled heat exchangers, whose design often relies on iterative testing or computationally intensive simulations. As a result, only a limited number of design points are usually examined, increasing the risk of missing optimal solutions. To address this, a novel modeling approach has been developed to rapidly predict the maximum temperature in a sequence of liquid-cooled battery cells during constant-current discharge. A response surface was formulated, based on varying flow rates and discharge currents. The central feature of the proposed approach is that, for each selected nonzero discharge current, the entire coolant-flow-rate dependence of the maximal temperature can be reconstructed from only two limiting thermal simulations: a zeroflow case and an idealized high-flow case. No simulations at intermediate flow rates are required. In the present study, five discharge-current levels were evaluated, requiring a total of ten simplified numerical simulations to construct the complete response surface. The total computational time required for these ten simplified simulations was approximately half that required for a single full-system CFD simulation. Once constructed, the response surface enables rapid prediction of the maximal temperature for arbitrary combinations of discharge current and coolant flow rate within the investigated range without additional numerical simulations. The predicted temperatures were compared with experimental data from 12 operating conditions, resulting in a mean absolute error of 1.1 °C and a maximum relative error of 7.8%. The method is demonstrated for cylindrical 18650 Li-Ion cells cooled by polymeric hollow-fiber channels and is intended primarily as a rapid screening tool for battery thermal management system design.

Anglický abstrakt

The growing demand for high-performance electric vehicles has highlighted the need for efficient thermal management of Li-Ion batteries. These systems are typically based on liquidcooled heat exchangers, whose design often relies on iterative testing or computationally intensive simulations. As a result, only a limited number of design points are usually examined, increasing the risk of missing optimal solutions. To address this, a novel modeling approach has been developed to rapidly predict the maximum temperature in a sequence of liquid-cooled battery cells during constant-current discharge. A response surface was formulated, based on varying flow rates and discharge currents. The central feature of the proposed approach is that, for each selected nonzero discharge current, the entire coolant-flow-rate dependence of the maximal temperature can be reconstructed from only two limiting thermal simulations: a zeroflow case and an idealized high-flow case. No simulations at intermediate flow rates are required. In the present study, five discharge-current levels were evaluated, requiring a total of ten simplified numerical simulations to construct the complete response surface. The total computational time required for these ten simplified simulations was approximately half that required for a single full-system CFD simulation. Once constructed, the response surface enables rapid prediction of the maximal temperature for arbitrary combinations of discharge current and coolant flow rate within the investigated range without additional numerical simulations. The predicted temperatures were compared with experimental data from 12 operating conditions, resulting in a mean absolute error of 1.1 °C and a maximum relative error of 7.8%. The method is demonstrated for cylindrical 18650 Li-Ion cells cooled by polymeric hollow-fiber channels and is intended primarily as a rapid screening tool for battery thermal management system design.

Klíčová slova

battery thermal management systems, cylindrical batteries, heat exchangers, polymeric hollow fibers

Klíčová slova v angličtině

battery thermal management systems, cylindrical batteries, heat exchangers, polymeric hollow fibers

Autoři

HVOŽĎA, J.; BOHÁČEK, J.; BARTULI, E.; MRÁZ, K.; VAKHRUSHEV, A.; KARIMI-SIBAKI, E.; RAUDENSKÝ, M.

Vydáno

16.09.2026

Nakladatel

Elsevier BV

Periodikum

Energy Conversion and Management-X

Svazek

32

Číslo

12

Stát

Spojené království Velké Británie a Severního Irska

Strany od

1

Strany do

9

Strany počet

9

URL

BibTex

@article{BUT212470,
  author="Jiří {Hvožďa} and Jan {Boháček} and Erik {Bartuli} and Kryštof {Mráz} and  {} and  {} and Miroslav {Raudenský}",
  title="Rapid prediction of maximal temperature in liquid-cooled li-ion battery modules: a case study using polymeric hollow fiber cooling channels",
  journal="Energy Conversion and Management-X",
  year="2026",
  volume="32",
  number="12",
  pages="1--9",
  doi="10.1016/j.ecmx.2026.102323",
  issn="2590-1745",
  url="https://doi.org/10.1016/j.ecmx.2026.102323"
}