Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikačního výsledku
CRAY, J.; VITOUŠ, J.; JIŘÍK, R.; TITARENKO, S.; BUCKLEY, D.
Originální název
Blind Estimation Versus Direct Measurement of the Arterial Input Function in Dynamic Contrast-Enhanced MRI of the Breast
Anglický název
Druh
Článek WoS
Originální abstrakt
Purpose Accurate arterial input functions (AIFs) are essential for quantitative dynamic contrast-enhanced (DCE) MRI, yet direct measurement is challenging and population-averaged AIFs neglect patient-specific variability. Blind deconvolution provides an alternative by estimating patient-specific AIFs directly from tissue data, up to a scale factor. This study compared blindly estimated AIFs with carefully measured aortic AIFs in breast DCE-MRI.Theory and Methods Data from 25 patients with breast cancer were analyzed, each with a carefully measured AIF. Blind AIF estimates were obtained using model-constrained deconvolution in the Perflab toolkit with both Tofts-Kety (TK) and two-compartment exchange (2CXM) tissue models. To help isolate AIF shape blind AIFs were scaled using cardiac output. These blind AIFs were compared with measured AIFs using scale-invariant and scale-dependent metrics which assess the similarity of the AIF shape.Results Blind estimates were obtained for all 25 patients with both tissue models. Compared with measured AIFs, blind estimates derived using the 2CXM showed stronger agreement across all metrics than those derived using the TK model. However, the weak correlation in scale-dependent metrics suggests limitations of cardiac output scaling.Conclusion Blind AIF estimation using the 2CXM provides more reliable recovery of AIF shape and dispersion than the TK model in breast DCE-MRI. While blind deconvolution shows promise for estimating local patient-specific AIFs other scaling strategies may need to be employed in practice.
Anglický abstrakt
Klíčová slova
arterial input function, breast cancer, dynamic contrast-enhanced MRI, perfusion
Klíčová slova v angličtině
Autoři
Vydáno
04.07.2026
Nakladatel
Wiley
Periodikum
Magnetic Resonance in Medicine
Svazek
96
Číslo
October 2026
Stát
Spojené státy americké
Strany od
1521
Strany do
2036
Strany počet
9
URL
https://onlinelibrary.wiley.com/doi/full/10.1002/mrm.70454
BibTex
@article{BUT211978, author="{} and Jiří {Vitouš} and Radovan {Jiřík} and {} and {}", title="Blind Estimation Versus Direct Measurement of the Arterial Input Function in Dynamic Contrast-Enhanced MRI of the Breast", journal="Magnetic Resonance in Medicine", year="2026", volume="96", number="October 2026", pages="9", doi="10.1002/mrm.70454", issn="0740-3194", url="https://onlinelibrary.wiley.com/doi/full/10.1002/mrm.70454" }