Detail publikačního výsledku

Case study of two domestic hot water storage concepts in residential heat pump systems

RUBINA, A.; PÍREK, O.; SALAJKA, R.; RUBINOVÁ, O.; FORMÁNEK, M.; SMUTKOVÁ, K.

Originální název

Case study of two domestic hot water storage concepts in residential heat pump systems

Anglický název

Case study of two domestic hot water storage concepts in residential heat pump systems

Druh

Článek WoS

Originální abstrakt

This case study presents a comparative analysis of real-world operation two residential domestic hot water (DHW) preparation methods both connected to their own air-to-water heat pump (HP) located in Central Europe. One system employs a conventional configuration with separate tanks and an internal heating coil (HP-B), while the other features a compact tank-in-tank setup where DHW is heated via an integrated buffer tank (HP-A). Both systems were monitored under real operational conditions, with seasonal and annual coefficients of performance (COP, SCOP) calculated to evaluate efficiency. In the absence of complete thermal output data for one system, a reconstruction method based on the other’s performance and known heat losses was applied. The findings confirm that DHW system design significantly affects seasonal efficiency, particularly during summer operation when heating DHW dominates the energy load. The energy cost savings on heating during summer months could reach 44 %. The tank-in-tank system showed higher electrical consumption and lower SCOP due to internal heat transfer dynamics and dual-function operation. The study further shows associated energy and cost differences and demonstrates a practical approach to comparing real-world systems offering insights for design optimization and operational strategy. The authors of the article used the results of their research and experience from implementations as very effective feedback for further research and development. The novelty and uniqueness of the article lie in the energy comparison of two different connections of the hot water and heating water storage tanks with heat source systems using an “air-to-water” heat pump. The benefit of the solution in question is evident from the technical and economic evaluation.

Anglický abstrakt

This case study presents a comparative analysis of real-world operation two residential domestic hot water (DHW) preparation methods both connected to their own air-to-water heat pump (HP) located in Central Europe. One system employs a conventional configuration with separate tanks and an internal heating coil (HP-B), while the other features a compact tank-in-tank setup where DHW is heated via an integrated buffer tank (HP-A). Both systems were monitored under real operational conditions, with seasonal and annual coefficients of performance (COP, SCOP) calculated to evaluate efficiency. In the absence of complete thermal output data for one system, a reconstruction method based on the other’s performance and known heat losses was applied. The findings confirm that DHW system design significantly affects seasonal efficiency, particularly during summer operation when heating DHW dominates the energy load. The energy cost savings on heating during summer months could reach 44 %. The tank-in-tank system showed higher electrical consumption and lower SCOP due to internal heat transfer dynamics and dual-function operation. The study further shows associated energy and cost differences and demonstrates a practical approach to comparing real-world systems offering insights for design optimization and operational strategy. The authors of the article used the results of their research and experience from implementations as very effective feedback for further research and development. The novelty and uniqueness of the article lie in the energy comparison of two different connections of the hot water and heating water storage tanks with heat source systems using an “air-to-water” heat pump. The benefit of the solution in question is evident from the technical and economic evaluation.

Klíčová slova

domestic hot water heating, air-to-water heat pump, tank-in-tank configuration, separate storage tanks, seasonal performance evaluation, internal heat transfer, field-based assessment

Klíčová slova v angličtině

domestic hot water heating, air-to-water heat pump, tank-in-tank configuration, separate storage tanks, seasonal performance evaluation, internal heat transfer, field-based assessment

Autoři

RUBINA, A.; PÍREK, O.; SALAJKA, R.; RUBINOVÁ, O.; FORMÁNEK, M.; SMUTKOVÁ, K.

Rok RIV

2026

Vydáno

06.03.2026

Periodikum

Buildings

Svazek

16

Číslo

5

Stát

Švýcarská konfederace

Strany počet

28

URL

BibTex

@article{BUT201667,
  author="Aleš {Rubina} and Ondřej {Pírek} and Radek {Salajka} and Olga {Rubinová} and Marian {Formánek} and Karolína {Smutková}",
  title="Case study of two domestic hot water storage concepts in residential heat pump systems",
  journal="Buildings",
  year="2026",
  volume="16",
  number="5",
  pages="28",
  doi="10.3390/buildings16051034",
  url="https://doi.org/10.3390/buildings16051034"
}