Self-gated Arterial Spin Labeling Perfusion Mapping of Myocardium Using Magnetic Resonance Imaging

VITOUŠ, J.; MACÍČEK, O.; JIŘÍK, R.

Originální název

Self-gated Arterial Spin Labeling Perfusion Mapping of Myocardium Using Magnetic Resonance Imaging

Anglický název

Self-gated Arterial Spin Labeling Perfusion Mapping of Myocardium Using Magnetic Resonance Imaging

Druh

Stať ve sborníku v databázi WoS či Scopus

Originální abstrakt

Myocardial perfusion MR provides useful information for diagnosis of several cardiac diseases and allows for treatment monitoring. Many methods have been proposed based on DCE-MRI or ASL. With the current slow drift from contrast agent administration in clinical setup, it is necessary to develop reliable methods that would replace DCE-MRI. ASL has always been a hope for a clean noninvasive method of perfusion measurement, but due to its issues it is still not widely accepted as a reliable method especially outside of the brain. We propose a method for perfusion measurement based on FAIR-ASL which internally does not require ECG measurement, uses advanced acquisition tweaks and compressed sensing subspace image reconstruction. We test the method in a preclinical setup, where high B0 fields and higher heart rates are the main issues. The acquired flow maps were comparable with state of the art methods, while giving a possibility of acquisition shortening or increased spatial resolution. We were able to obtain perfusion maps of the whole cardiac cycle with 315 um spatial resolution and 1 mm slice thickness from a 15- minutes acquisition. The acquisition time could possibly be reduced further, by additional optimization of the pulse sequence.

Anglický abstrakt

Myocardial perfusion MR provides useful information for diagnosis of several cardiac diseases and allows for treatment monitoring. Many methods have been proposed based on DCE-MRI or ASL. With the current slow drift from contrast agent administration in clinical setup, it is necessary to develop reliable methods that would replace DCE-MRI. ASL has always been a hope for a clean noninvasive method of perfusion measurement, but due to its issues it is still not widely accepted as a reliable method especially outside of the brain. We propose a method for perfusion measurement based on FAIR-ASL which internally does not require ECG measurement, uses advanced acquisition tweaks and compressed sensing subspace image reconstruction. We test the method in a preclinical setup, where high B0 fields and higher heart rates are the main issues. The acquired flow maps were comparable with state of the art methods, while giving a possibility of acquisition shortening or increased spatial resolution. We were able to obtain perfusion maps of the whole cardiac cycle with 315 um spatial resolution and 1 mm slice thickness from a 15- minutes acquisition. The acquisition time could possibly be reduced further, by additional optimization of the pulse sequence.

Klíčová slova

ASL, MRI

Klíčová slova v angličtině

ASL, MRI

Autoři

VITOUŠ, J.; MACÍČEK, O.; JIŘÍK, R.

Vydáno

13.09.2024

Nakladatel

Computing in Cardiology

Kniha

CINC 2024

Periodikum

Computing in Cardiology

Svazek

51

Stát

Spojené státy americké

Strany počet

4

URL

BibTex

@inproceedings{BUT197878,
  author="Jiří {Vitouš} and Ondřej {Macíček} and Radovan {Jiřík}",
  title="Self-gated Arterial Spin Labeling Perfusion Mapping of Myocardium
Using Magnetic Resonance Imaging",
  booktitle="CINC 2024",
  year="2024",
  journal="Computing in Cardiology",
  volume="51",
  pages="4",
  publisher="Computing in Cardiology",
  doi="10.22489/CinC.2024.345",
  url="https://cinc.org/archives/2024/pdf/CinC2024-345.pdf"
}