HORYNOVÁ, M.; REMEŠOVÁ, M.; KLAKURKOVÁ, L.; DVOŘÁK, K.; ROČŇÁKOVÁ, I.; YAN, S.; ČELKO, L.; SONG, G. L.
Originální název
Design of tailored biodegradable implants: The effect of voltageon electrodeposited calcium phosphate Coatings on puremagnesium
Anglický název
Druh
Článek WoS
Originální abstrakt
Magnesium, as a biodegradable metal, offers great potential for use as a tempo-rary implant material, which dissolves in the course of bone tissue healing. It cansufficiently support the bone and promote the bone healing process. However, thecorrosion resistance of magnesium implants must be enhanced before its applica-tion in clinical practice. A promising approach of enhancing the corrosion resis-tance is deposition of bioactive coating, which can reduce the corrosion rate ofthe implants and promote bone healing. Therefore, a well‐designed substrate‐coat-ing system allowing a good control of the degradation behavior is highly desir -able for tailored implants for specific groups of patients with particular needs. Inthis con tribution, the influence of coating formation conditions on the charact eris-tics of potentiostatically elect rodeposited CaP coatings on magnesium substratewas evaluated. Results showed that potential variation led to formation of coat-ings with the same chemical composition, but very different morphologies.Parameters that mostly influence the coating performance, such as the thickness,uniformity, deposits size, and orientation, varied from produced coating to coat-ing. These characteristics of CaP coatings on magnesium were controlled by coat-ing formation potential, and it was demonstrated that the electrodeposition couldbe a promising coating technique for production of tailored magnesium‐ CaPimplants.
Anglický abstrakt
Klíčová slova
biodegradation; calcium phosphate; coatings; electrodeposition; magnesium
Klíčová slova v angličtině
Autoři
Rok RIV
2019
Vydáno
01.01.2019
Nakladatel
The American Ceramic Society
Místo
Spojené státy americké
ISSN
0002-7820
Periodikum
JOURNAL OF THE AMERICAN CERAMIC SOCIETY
Svazek
102
Číslo
1
Stát
Strany od
123
Strany do
135
Strany počet
13
URL
https://onlinelibrary.wiley.com/doi/abs/10.1111/jace.15888
Plný text v Digitální knihovně
http://hdl.handle.net/11012/245259
BibTex
@article{BUT149196, author="Miroslava {Horynová} and Michaela {Remešová} and Lenka {Klakurková} and Karel {Dvořák} and Ivana {Ročňáková} and Shaokun {Yan} and Ladislav {Čelko} and Guang-Ling {Song}", title="Design of tailored biodegradable implants: The effect of voltageon electrodeposited calcium phosphate Coatings on puremagnesium", journal="JOURNAL OF THE AMERICAN CERAMIC SOCIETY", year="2019", volume="102", number="1", pages="123--135", doi="10.1111/jace.15888", issn="0002-7820", url="https://onlinelibrary.wiley.com/doi/abs/10.1111/jace.15888" }
Dokumenty
2018-ART-13--JACE-Design of tailored biodegradable implants-hor-rem-klak-dv-roc--BUT_LIBjace.15888-accepted