Humidity Measurement and Adjustment at Environmental Conditions

AUTRATA, R., JIRÁK, J., NEDĚLA, V., ŠPINKA, J.

Originální název

Humidity Measurement and Adjustment at Environmental Conditions

Anglický název

Humidity Measurement and Adjustment at Environmental Conditions

Druh

Stať ve sborníku v databázi WoS či Scopus

Originální abstrakt

When we are detecting signal electrons with an ionization detector in ESEM, the most advantageous is to use, with respect to the effectiveness of ionization, environment of water vapours in the specimen chamber. The most suitable are saturated water vapours (relative humidity of 100%). This environment is also advantageous for observation of specimens containing water. At pumping of the specimen chamber to the working pressure (typically around 1000 Pa), in the case of wet specimens, evaporation of specimen can occur, or on the contrary, condensation of water on them. It means, that in some cases the specimen will not remain in the original state. That is why we try to adjust and optimize the pumping procedure and pumping of water vapors to minimize deformation of the observed specimens.

Anglický abstrakt

When we are detecting signal electrons with an ionization detector in ESEM, the most advantageous is to use, with respect to the effectiveness of ionization, environment of water vapours in the specimen chamber. The most suitable are saturated water vapours (relative humidity of 100%). This environment is also advantageous for observation of specimens containing water. At pumping of the specimen chamber to the working pressure (typically around 1000 Pa), in the case of wet specimens, evaporation of specimen can occur, or on the contrary, condensation of water on them. It means, that in some cases the specimen will not remain in the original state. That is why we try to adjust and optimize the pumping procedure and pumping of water vapors to minimize deformation of the observed specimens.

Klíčová slova

Humidity,ESEM,Environmental Conditions

Klíčová slova v angličtině

Humidity,ESEM,Environmental Conditions

Autoři

AUTRATA, R., JIRÁK, J., NEDĚLA, V., ŠPINKA, J.

Rok RIV

2011

Vydáno

01.01.2004

Nakladatel

Mullerová Ilona

Místo

Brno

ISBN

80-239-3246-2

Kniha

Recent Trends in Charged Patricle Optics and Surface Physics Instrumentation

Svazek

2004

Strany od

7

Strany počet

2

URL

BibTex

@inproceedings{BUT12463,
  author="Rudolf {Autrata} and Josef {Jirák} and Vilém {Neděla} and Jiří {Špinka}",
  title="Humidity Measurement and Adjustment at Environmental Conditions",
  booktitle="Recent Trends in Charged Patricle Optics and Surface Physics Instrumentation",
  year="2004",
  volume="2004",
  number="9",
  pages="2",
  publisher="Mullerová Ilona",
  address="Brno",
  isbn="80-239-3246-2",
  url="http://www.isibrno.cz"
}