Detail publikačního výsledku

Can Laplace law replace more sophisticated analyses of aortic aneurysms?

MAN, V.; NOVÁK, K.; POLZER, S.; BURŠA, J.

Originální název

Can Laplace law replace more sophisticated analyses of aortic aneurysms?

Anglický název

Can Laplace law replace more sophisticated analyses of aortic aneurysms?

Druh

Abstrakt

Originální abstrakt

The simple quasi-linear constitutive model without residual stresses and without taking the AAA unloaded shape into account can offer acceptable results for simple geometrical shapes but is not applicable for credible evaluation of stresses in patient specific models of AAAs

Anglický abstrakt

The simple quasi-linear constitutive model without residual stresses and without taking the AAA unloaded shape into account can offer acceptable results for simple geometrical shapes but is not applicable for credible evaluation of stresses in patient specific models of AAAs

Klíčová slova

Laplace law; computational analysis; constitutive models; abdominal aortic aneurysm; residual stresses

Klíčová slova v angličtině

Laplace law; computational analysis; constitutive models; abdominal aortic aneurysm; residual stresses

Autoři

MAN, V.; NOVÁK, K.; POLZER, S.; BURŠA, J.

Rok RIV

2016

Vydáno

04.11.2014

Místo

Špičák

Strany počet

2