PORTABLE DEVICE FOR PESTICIDE TOXICITY ANALYSIS

HÁZE, J.

Originální název

PORTABLE DEVICE FOR PESTICIDE TOXICITY ANALYSIS

Anglický název

PORTABLE DEVICE FOR PESTICIDE TOXICITY ANALYSIS

Druh

Stať ve sborníku v databázi WoS či Scopus

Originální abstrakt

Fast detection of pesticide toxicity in field conditions is not fully solved yet. The new device for field measurement of organophosporous pesticides toxicity is described. The detection is based on the inhibition of acetylcholinesterase. The enzyme acetylcholinesterase is immobilized on a miniature electrochemical detector made by thick film technology forming together a biosensor. The dimensions of biosensor are 7,35 x 25,4 mm. The biosensor is placed in flow chamber which assures the reproducible hydrodynamic conditions near of active surface of the sensor. The analyzed sample is detected in the flow of supporting buffer. The biosensor detects the integral sample toxicity. It is destinated for detection of traces of pesticides in washout from leaves for direct measurment in rivers, ponds, vaste waters and drinking water sources. The preconcentration of sample is possible. The detection limit varies in wide range depending on the toxicity of pesticide.

Anglický abstrakt

Fast detection of pesticide toxicity in field conditions is not fully solved yet. The new device for field measurement of organophosporous pesticides toxicity is described. The detection is based on the inhibition of acetylcholinesterase. The enzyme acetylcholinesterase is immobilized on a miniature electrochemical detector made by thick film technology forming together a biosensor. The dimensions of biosensor are 7,35 x 25,4 mm. The biosensor is placed in flow chamber which assures the reproducible hydrodynamic conditions near of active surface of the sensor. The analyzed sample is detected in the flow of supporting buffer. The biosensor detects the integral sample toxicity. It is destinated for detection of traces of pesticides in washout from leaves for direct measurment in rivers, ponds, vaste waters and drinking water sources. The preconcentration of sample is possible. The detection limit varies in wide range depending on the toxicity of pesticide.

Klíčová slova v angličtině

portable device, pesticide toxicity, microfluidic

Autoři

HÁZE, J.

Vydáno

01.01.2003

Nakladatel

Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií

Místo

Brno

ISBN

80-214-2379-X

Kniha

Proceedings of 9th conference and competition Student EEICT 2003, Volume 3

Strany od

440

Strany počet

5

BibTex

@inproceedings{BUT10486,
  author="Jiří {Háze}",
  title="PORTABLE DEVICE FOR PESTICIDE TOXICITY ANALYSIS",
  booktitle="Proceedings of 9th conference and competition Student EEICT 2003, Volume 3",
  year="2003",
  number="1",
  pages="5",
  publisher="Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií",
  address="Brno",
  isbn="80-214-2379-X"
}