Detail publikace

Assessment of heart position in a torso model using an inverse solution

ŠVEHLÍKOVÁ, J. LENKOVÁ, J. DRKOŠOVÁ, A. FOLTIN, M. TYŠLER, M.

Originální název

Assessment of heart position in a torso model using an inverse solution

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

Knowledge of actual heart position is important for finding results in inverse problem of electrocardiography. Magnetic resonance images of real subjects revealed large variability of the heart position in relation to ecg lead V2 usually placed in the 4th intercostal space and considered as the anatomical reference. The use of standard torso model in which the location of modeled heart is constant thus cannot reflect its actual position sufficiently. The method for finding the approximate position of heart in a standard torso model corresponding to the actual heart position in an observed subject is presented. Position of single dipole obtained by an inverse solution from body surface potential measurements was used to locate the initial site of ventricular depolarization and suggested as representative position of the left ventricular septum. This approach was studied in 25 subjects with well documented geometry and measured ecg potentials in 62 leads. For each subject the heart in standard torso model was moved to a new position corresponding to the inversely estimated initial site of ventricular depolarization. The individually estimated heart position in the standard torso model better corresponded to the real torso geometry configuration than that derived from the anatomical leads placement.

Klíčová slova

standard torso model, inverse solution, integral maps, position of heart

Autoři

ŠVEHLÍKOVÁ, J.; LENKOVÁ, J.; DRKOŠOVÁ, A.; FOLTIN, M.; TYŠLER, M.

Rok RIV

2011

Vydáno

27. 4. 2011

Nakladatel

Institute of Measurement Science SAS

Místo

Bratislava

ISBN

978-80-969672-4-7

Kniha

MEASUREMENT 2011: Proceedings of the 8th International Conference on Measurement

Strany od

297

Strany do

300

Strany počet

4

BibTex

@inproceedings{BUT74245,
  author="Jana {Švehlíková} and Jana {Lenková} and Alena {Kubičková} and Miroslav {Foltin} and Milan {Tyšler}",
  title="Assessment of heart position in a torso model using an inverse solution",
  booktitle="MEASUREMENT 2011: Proceedings of the 8th International Conference on Measurement",
  year="2011",
  pages="297--300",
  publisher="Institute of Measurement Science SAS",
  address="Bratislava",
  isbn="978-80-969672-4-7"
}