Originální abstrakt
The roof is assembled of precast members suspended on a net of cables anchored at inclined arches. Prestressing done after casting the joints between the arches and among the precast members guarantees the siffness of the roof. The model is in the scale 1:10, the arches are formed by steel pipes filed with high-strength concrete, the precast members are from light-weight concrete. The structure is described in terms of the structural lsolution and static analysis, the model lis described in terms of the model similarity, production and erection.
Anglický abstrakt
Klíčová slova
space structure; prestressed concrete; membrane; bearing and prestressing cables; lightweight and high-strength concrete; static analysis
Klíčová slova v angličtině
Autoři
Vydáno
03.12.2007
Nakladatel
University IUAV
Místo
Venice-Italy
Kniha
IASS 2007: Shell and Spatial Structures
Edice
2007
Strany od
325
Strany do
326
Strany počet
2
BibTex
@inproceedings{BUT25695, author="Jiří {Stráský} and Pavel {Kaláb}", title="Model test of the prestressed concrete membrane", booktitle="IASS 2007: Shell and Spatial Structures", year="2007", series="2007", number="1", pages="325--326", publisher="University IUAV", address="Venice-Italy" }