Originální abstrakt
This article deals with physical and chemical processes during measurement with an inductive flowmeter. A theoretical model and an example of numerical solution are presented here. We prepared numerical models based on the combined finite element method (FEM) and the finite volume method (FVM) of one of the three variants and computed the output voltage of the flowmeter electrodes. The model joins the magnetic, the electric and the current fields, the flow field and a chemical nonlinear ion model. The results were obtained by means of the FEM/FVM as a main application in ANSYS software.
Anglický abstrakt
Klíčová slova
magnetohydrodynamics, fluid flow measurement, finite element methods, turbulent media, Hall effect
Klíčová slova v angličtině
Autoři
Rok RIV
2010
Vydáno
23.05.2007
Nakladatel
Wydrukowano w Zakladzie Graficznym Politechniki Slaskiej w Gliwicach
ISBN
978-83-85940-29-6
Kniha
IC - SPETO 2007
Strany od
63
Strany do
64
Strany počet
2
BibTex
@inproceedings{BUT23688, author="Pavel {Fiala} and Tomáš {Jirků} and Ivo {Běhunek}", title="Evaluation of EHD model of the inductive flowmeter", booktitle="IC - SPETO 2007", year="2007", pages="63--64", publisher="Wydrukowano w Zakladzie Graficznym Politechniki Slaskiej w Gliwicach", isbn="978-83-85940-29-6" }