Originální abstrakt

The problem of the damage of the bioimplants is very important today. In the endoprosthesis surgery there is a large percentage of implant defects, which cause the failure of the whole prosthesis. One kind of the total hip replacement functionality loss is acetabular cup pull-off from pelvis bone. This paper is aimed at manufacture perturbations (shape deviations) analysis as one of the possible reasons to this kind of failure. Dimension and of geometry manufacturing perturbations (roundness) were analyzed in detail. It was found, that these perturbations affect considered values of contact pressure and frictional moment. Contact pressure and frictional moment are quantities affecting replacement success and durability.

Anglický abstrakt

The problem of the damage of the bioimplants is very important today. In the endoprosthesis surgery there is a large percentage of implant defects, which cause the failure of the whole prosthesis. One kind of the total hip replacement functionality loss is acetabular cup pull-off from pelvis bone. This paper is aimed at manufacture perturbations (shape deviations) analysis as one of the possible reasons to this kind of failure. Dimension and of geometry manufacturing perturbations (roundness) were analyzed in detail. It was found, that these perturbations affect considered values of contact pressure and frictional moment. Contact pressure and frictional moment are quantities affecting replacement success and durability.

Klíčová slova

total hip replacement, shape deviations, roundness, contact pressure, frictional moment

Klíčová slova v angličtině

total hip replacement, shape deviations, roundness, contact pressure, frictional moment

Autoři

FUIS, V.; KOUKAL, M.; FLORIAN, Z.; JANÍČEK, P.

Rok RIV

2014

Vydáno

25.09.2013

Nakladatel

Springer

Místo

Seville

ISBN

978-3-319-00845-5

Kniha

XI Mediterranean Conference on Medical and Biological Engineering and Computing 2013

Edice

IFMBE Proceedings

ISSN

1680-0737

Periodikum

IFMBE Proceedings

Svazek

41

Stát

Francouzská republika

Strany od

89

Strany do

92

Strany počet

4

BibTex

@inproceedings{BUT104713,
  author="Vladimír {Fuis} and Milan {Koukal} and Zdeněk {Florian} and Přemysl {Janíček}",
  title="Computational Modelling of the Shape Deviations of the Sphere Surfaces of Ceramic Heads of Hip Joint Replacement",
  booktitle="XI Mediterranean Conference on Medical and Biological Engineering and Computing 2013",
  year="2013",
  series="IFMBE Proceedings",
  journal="IFMBE Proceedings",
  volume="41",
  number="Vol. 41",
  pages="89--92",
  publisher="Springer",
  address="Seville",
  doi="10.1007/978-3-319-00846-2\{_}22",
  isbn="978-3-319-00845-5",
  issn="1680-0737"
}