Course detail
Computer Aided Building Physics Application
FAST-CH003Acad. year: 2018/2019
Real recovery software for Building Physics in the design and construction assessment in accordance with applicable legislation.
In particular, the assessment of structures in terms of thermal and acoustic techniques
Verification of thermal comfort, sound and light microclimate of buildings.
The calculation and design is to optimize the structural design of the building envelope and the doors and windows, including the resolution of structural details.
Language of instruction
Number of ECTS credits
Mode of study
Guarantor
Department
Learning outcomes of the course unit
Prerequisites
Co-requisites
Planned learning activities and teaching methods
Assesment methods and criteria linked to learning outcomes
To pass the examination in the written test to achieve leas a majority of points.
Course curriculum
2en Practical use of software for building heat engineering solution of one-dimensional temperature field for the unsteady state
3rd to 4th Modelling and assessment of selected detail using a two-dimensional temperature field.
5th to 6th Thermal stability of a room - a critical assessment of the room in terms of maximal increase of temperature and a maximum temperature of a room in summer
7th Functional requirements of the day and insolation of buildings
8th Rating daylight factor
9th Structural and energetic properties of the building, the heat transfer through the building envelope
10th Energy performance of buildings
11th Functional requirements for acoustics
12th Rating insulation separating structures
13th Verifying the suitability of design of structures including doors and windows in terms of building physics (overall concept of the building and individual design - optimization requirements in terms of thermal physics, acoustics, daylighting and insolation of buildings)
Work placements
Aims
Specification of controlled education, way of implementation and compensation for absences
Recommended optional programme components
Prerequisites and corequisites
Basic literature
Recommended reading
Classification of course in study plans
- Programme N-K-C-SI Master's
branch S , 1 year of study, winter semester, compulsory
branch S , 1 year of study, winter semester, compulsory - Programme N-P-C-SI Master's
branch S , 1 year of study, winter semester, compulsory
branch S , 1 year of study, winter semester, compulsory - Programme N-P-E-SI Master's
branch S , 1 year of study, winter semester, compulsory
branch S , 1 year of study, winter semester, compulsory
Type of course unit
Lecture
Teacher / Lecturer
Syllabus
2en Practical use of software for building heat engineering solution of one-dimensional temperature field for the unsteady state
3rd to 4th Modelling and assessment of selected detail using a two-dimensional temperature field.
5th to 6th Thermal stability of a room - a critical assessment of the room in terms of maximal increase of temperature and a maximum temperature of a room in summer
7th Functional requirements of the day and insolation of buildings
8th Rating daylight factor
9th Structural and energetic properties of the building, the heat transfer through the building envelope
10th Energy performance of buildings
11th Functional requirements for acoustics
12th Rating insulation separating structures
13th Verifying the suitability of design of structures including doors and windows in terms of building physics (overall concept of the building and individual design - optimization requirements in terms of thermal physics, acoustics, daylighting and insolation of buildings)
Exercise
Teacher / Lecturer
Syllabus
2.Detailed introduction to the program Heat 2011. Heat transfer coefficient, together with a thermal bridge, balance condensation and evaporation of water vapor with consideration of the actual effectiveness of the vapor layer, drop touch the floor temperature.
3., 4.Solution selected details (min. 2 details) using a two-dimensional temperature field - program AREA 2011.
5., 6.Program 2011 Stability and Simulation 2011. Assessment of the critical rooms in winter and summer.
7., 8. Assessment of daylight factor using WDLS (required continuity of the Stability and Simulation). Optimizing the window size so as to meet the requirements in terms of thermal stability and daylight factor.
9. The transmission of heat through the building envelope according to CSN 73 0540-2:2011, the average heat transfer coefficient, the label of the building envelope (loss programs 2011).
10., 11. Evaluation of energy performance according to the current legislation - an amendment to Act No. 406/2000 Coll. Energy Management Act (Act No. 318/2012 Coll.) and amendment of Decree No. 148/2007 Coll. - Energy Program
12.Assessment of internal partition structures in terms of airborne and impact sound insulation in the "Attenuation".
13. Credits