Publication detail

EXPERIMENTAL STUDIES OF THE POLYMERIC HOLLOW FIBER HEAT EXCHANGERS EXCHANGERS

ASTROUSKI, I. RAUDENSKÝ, M.

Original Title

EXPERIMENTAL STUDIES OF THE POLYMERIC HOLLOW FIBER HEAT EXCHANGERS EXCHANGERS

English Title

EXPERIMENTAL STUDIES OF THE POLYMERIC HOLLOW FIBER HEAT EXCHANGERS EXCHANGERS

Type

abstract

Language

en

Original Abstract

The polymeric heat exchangers from hollow fibers were developed and tested in the Heat Transfer and Fluid Flow Laboratory at Brno University of Technology. Heat exchangeres were built based on polypropylene hollow fibers with an outer diameter from 0.4 to 0.8 mm. They were tested for both counter flow and cross flow for water-air and water-water applications. The results of the thermal performance test are described in the paper.

English abstract

The polymeric heat exchangers from hollow fibers were developed and tested in the Heat Transfer and Fluid Flow Laboratory at Brno University of Technology. Heat exchangeres were built based on polypropylene hollow fibers with an outer diameter from 0.4 to 0.8 mm. They were tested for both counter flow and cross flow for water-air and water-water applications. The results of the thermal performance test are described in the paper.

Keywords

polymer, hollow fiber, heat exchanger, heat transfer

Released

15.10.2012

Publisher

Institut za kovinske materiale in tehnologije

Location

Ljubljana 2012

ISBN

978-961-92518-5-0

Book

20th jubilee conference on materials and technology. Program and book of abstracts

Edition

1

Issue number

20

Pages from

35

Pages to

35

Pages count

1

URL

Documents

BibTex


@misc{BUT98432,
  author="Ilja {Astrouski} and Miroslav {Raudenský}",
  title="EXPERIMENTAL STUDIES OF THE POLYMERIC HOLLOW FIBER HEAT EXCHANGERS EXCHANGERS",
  annote="The polymeric heat exchangers from hollow fibers were developed and tested in the Heat Transfer
and Fluid Flow Laboratory at Brno University of Technology. Heat exchangeres were built based on
polypropylene hollow fibers with an outer diameter from 0.4 to 0.8 mm. They were tested for both
counter flow and cross flow for water-air and water-water applications. The results of the thermal performance
test are described in the paper.",
  address="Institut za kovinske materiale in tehnologije",
  booktitle="20th jubilee conference on materials and technology. Program and book of abstracts",
  chapter="98432",
  edition="1",
  howpublished="online",
  institution="Institut za kovinske materiale in tehnologije",
  year="2012",
  month="october",
  pages="35--35",
  publisher="Institut za kovinske materiale in tehnologije",
  type="abstract"
}