Original Title
The leakage inductance dependence on HF transformer winding arrangement
English Title
Type
Paper in proceedings (conference paper)
Original Abstract
The series resonant converter often uses the leakage inductance of transformers as resonant inductance in series with resonance capacitor. So the resonant capacitor is used to compensate the leakage inductance on set switching frequency. The leakage inductance of transformer can be affected in wide range, just by different arrangement of transformer windings around the core. It means that in the most cases the additional inductor neednt to be used.
English abstract
Keywords
resonant converter, leakage inductance, series resonant converter, transformer
Key words in English
Authors
RIV year
2014
Released