MAZŮREK, I.; ROUPEC, J.; KLAPKA, M.; STRECKER, Z.
Original Title
Load and rheometric unit for the test of magnetorheological fluid
English Title
Type
Peer-reviewed article not indexed in WoS or Scopus
Original Abstract
The article describes the original design of a slit flow rheometer. The behavioural problems of MR fluids and the main deviation from the commonly introduced Bingham model, which describes the MR fluid, are explained at the beginning of this article. Furthermore, the usual operating parameters of the MR fluids and devices are defined, such as: shear rate, viscosity in the off-state, yield stress, their dependence on temperature and the expected life of the filling. In the absence of a suitable rheometer a new design of rheometer was proposed, which allows long-term testing of MR fluids under real loading conditions. This article describes the important details of the construction. Particular attention is devoted to temperature measurement, calibration of the rheometer and data analysis, including mathematical tools and statistical evaluation of a set of measured points.
English abstract
Keywords
MR fluid, MR damper, magnetorheological, slit flow rheometer, high shear rates
Key words in English
Authors
RIV year
2014
Released
28.02.2013
Publisher
Springer Netherlands
ISBN
0025-6455
Periodical
MECCANICA
Volume
48
Number
3
State
Republic of Italy
Pages from
631
Pages to
641
Pages count
11
Full text in the Digital Library
http://hdl.handle.net/
BibTex
@article{BUT94621, author="Ivan {Mazůrek} and Jakub {Roupec} and Milan {Klapka} and Zbyněk {Strecker}", title="Load and rheometric unit for the test of magnetorheological fluid", journal="MECCANICA", year="2013", volume="48", number="3", pages="631--641", issn="0025-6455" }