Přístupnostní navigace
E-application
Search Search Close
Publication result detail
KŘÍŽKOVÁ, S.; HÚSKA, D.; BEKLOVÁ, M.; HUBÁLEK, J.; ADAM, V.; TRNKOVÁ, L.; KIZEK, R.
Original Title
PROTEIN-BASED ELECTROCHEMICAL BIOSENSOR FOR DETECTION OF SILVER(I) IONS
English Title
Type
Peer-reviewed article not indexed in WoS or Scopus
Original Abstract
The suggested biosensor responded well to higher silver(I) ion concentrations. The relative standard deviation for measurements of concentrations higher than 50 mu M was approximately 2% (n = 8). In the case of concentrations lower than 10 mu M, the relative standard deviation increased to 10% (n = 8). The detection limit (3 signal/noise) for silver(I) ions was estimated as 500 nM. Environ. Toxicol. Chem. 2010; 29: 492-496.
English abstract
Keywords
Silver; Biosensors; Voltammetry; Interaction
Key words in English
Authors
RIV year
2011
Released
10.03.2010
Publisher
SETAC PRESS
Location
1010 N 12TH AVE, PENSACOLA, FL 32501-3367 USA
ISBN
0730-7268
Periodical
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY
Volume
29
Number
3
State
United States of America
Pages from
492
Pages to
496
Pages count
5
BibTex
@article{BUT50228, author="Soňa {Křížková} and Dalibor {Húska} and Miroslava {Beklová} and Jaromír {Hubálek} and Vojtěch {Adam} and Libuše {Trnková} and René {Kizek}", title="PROTEIN-BASED ELECTROCHEMICAL BIOSENSOR FOR DETECTION OF SILVER(I) IONS", journal="ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY", year="2010", volume="29", number="3", pages="492--496", issn="0730-7268" }