Detail publikačního výsledku

Possibility increase cooling tower service life in terms of longterm monitoring

BYDŽOVSKÝ, J.; DUFKA, A.; ŠNIRCH, Z.

Original Title

Possibility increase cooling tower service life in terms of longterm monitoring

English Title

Possibility increase cooling tower service life in terms of longterm monitoring

Type

Paper in proceedings (conference paper)

Original Abstract

In terms of long-term monitoring of records from long-term cooling towers construction monitoring tower we have to be able to unite the records and use them for new progressive complex technology, susceptible to define time of service life and dependability of cooling tower as reinforced construction. Paper more precisely deal with influence of repair action on service life and degradation processes at construction. Monitored dependencies are then reflect on degradation curves each for a singles construction characteristics (compression strength of concrete, degradation of surface, volume of carbonatation etc.).

English abstract

In terms of long-term monitoring of records from long-term cooling towers construction monitoring tower we have to be able to unite the records and use them for new progressive complex technology, susceptible to define time of service life and dependability of cooling tower as reinforced construction. Paper more precisely deal with influence of repair action on service life and degradation processes at construction. Monitored dependencies are then reflect on degradation curves each for a singles construction characteristics (compression strength of concrete, degradation of surface, volume of carbonatation etc.).

Keywords

Possibility increase cooling tower service life in terms of longterm monitoring

Key words in English

Possibility increase cooling tower service life in terms of longterm monitoring

Authors

BYDŽOVSKÝ, J.; DUFKA, A.; ŠNIRCH, Z.

Released

25.05.2007

Publisher

Academic Society "Matei - Teiu Botez" Iasi, Romania

Location

Iasi, Romania

ISBN

978-973-8955-14-1

Book

Computational Civil Engineering 2007

Edition

1

Pages from

656

Pages to

663

Pages count

8

Full text in the Digital Library

BibTex

@inproceedings{BUT23160,
  author="Jiří {Bydžovský} and Amos {Dufka} and Zdeněk {Šnirch}",
  title="Possibility increase cooling tower service life in terms of longterm monitoring",
  booktitle="Computational Civil Engineering 2007",
  year="2007",
  series="1",
  number="1",
  pages="656--663",
  publisher="Academic Society {"}Matei - Teiu Botez{"} Iasi, Romania",
  address="Iasi, Romania",
  isbn="978-973-8955-14-1"
}