Original Abstract

INCONEL 713 LC is popular material for more exposed parts of turbine engines. These parts are usually exposured to high dynamic stress (fatigue processes, creep) and variable temperatures in corrosion environment (hot corrosion, oxidation and erosion). The most frequent failure of these parts is fatigue damage, which is started from inclusions at the surface. Topography of the surface of IN 713 LC in as received state and after low cycle fatigue tests at room temperature 23C and 800C was studied. Surface relief was formed by slip bands (intrusions and extrusions), which are generated by mechanism of microplastic deformation. Surface topography was measured by means of laser scanning confocal microscope LEXT OLS3000 (Olympus). Achieved results were compared with AFM Autoprobe (VEECO) and SEM (Philips XL30) measurements.

English abstract

INCONEL 713 LC is popular material for more exposed parts of turbine engines. These parts are usually exposured to high dynamic stress (fatigue processes, creep) and variable temperatures in corrosion environment (hot corrosion, oxidation and erosion). The most frequent failure of these parts is fatigue damage, which is started from inclusions at the surface. Topography of the surface of IN 713 LC in as received state and after low cycle fatigue tests at room temperature 23C and 800C was studied. Surface relief was formed by slip bands (intrusions and extrusions), which are generated by mechanism of microplastic deformation. Surface topography was measured by means of laser scanning confocal microscope LEXT OLS3000 (Olympus). Achieved results were compared with AFM Autoprobe (VEECO) and SEM (Philips XL30) measurements.

Keywords

AFM, Confocal microscopy, fatique test

Key words in English

AFM, Confocal microscopy, fatique test

Authors

ČELKO, L.; POSPÍŠILOVÁ, S.; JULIŠ, M.; TOMANEC, O.; PODRÁBSKÝ, T.

Released

01.06.2006

Publisher

RMS Royal Microscopical Society

Location

RMS Royal Microscopical Society, 37/38 St.Clements, Oxford OX4 IAJ, UK

Book

Microscience 2006

Edition

2006

Pages from

54

Pages to

54

Pages count

1

BibTex

@inproceedings{BUT19781,
  author="Ladislav {Čelko} and Simona {Hutařová} and Martin {Juliš} and Ondřej {Tomanec} and Tomáš {Podrábský}",
  title="Comparison of INCONEL 713 LC surface measurements by AFM and Confocal microscopy after low cyclic fatigue test",
  booktitle="Microscience 2006",
  year="2006",
  series="2006",
  number="1",
  pages="54--54",
  publisher="RMS Royal Microscopical Society",
  address="RMS Royal Microscopical Society, 37/38 St.Clements, Oxford OX4 IAJ, UK"
}