Applied result detail

ICP Accelerometer Signal Conversion Tool for Railway Superstructure Measurement Area

SMUTNÝ, J.

Original Title

ICP Accelerometer Signal Conversion Tool for Railway Superstructure Measurement Area

English Title

ICP Accelerometer Signal Conversion Tool for Railway Superstructure Measurement Area

Type

Functioning sample

Abstract

The created functional sample represents an interface module for measuring ICP accelerometers. The module is designed primarily for the needs of the Sbox datalogger (FV2023_1) and measurements on railway infrastructure. However, the module is designed in such a way that it can be used with a whole range of other devices, i.e. especially with those that do not allow this option. The module enables the measurement of single-axis and three-axis accelerometer types. At the same time, another connector is available on the side for connecting the LVDT linear displacement sensor from Inelta, type ISDT10-K2-2405. This measurement input can be interchanged with the "Z" axis input of the accelerometer in the case of using two uniaxial accelerometers. It is connected to a data logger or central measuring station via the Canon 9-pin connector. The supply voltage of unit is 5 V. Parameter switching is realized using DIP switches. The device is built into a waterproof box with IP65 protection.

Abstract in English

The created functional sample represents an interface module for measuring ICP accelerometers. The module is designed primarily for the needs of the Sbox datalogger (FV2023_1) and measurements on railway infrastructure. However, the module is designed in such a way that it can be used with a whole range of other devices, i.e. especially with those that do not allow this option. The module enables the measurement of single-axis and three-axis accelerometer types. At the same time, another connector is available on the side for connecting the LVDT linear displacement sensor from Inelta, type ISDT10-K2-2405. This measurement input can be interchanged with the "Z" axis input of the accelerometer in the case of using two uniaxial accelerometers. It is connected to a data logger or central measuring station via the Canon 9-pin connector. The supply voltage of unit is 5 V. Parameter switching is realized using DIP switches. The device is built into a waterproof box with IP65 protection.

Keywords

Railway superstructure, Sbox datalogger, ICP accelerometers, inductive displacement sensor

Key words in English

Railway superstructure, Sbox datalogger, ICP accelerometers, inductive displacement sensor

Location

Místnosti ústavu UŽKS C242, C161, Veveří 95, Brno

Licence fee

The result is being used by the owner

www

ftp://147.229.162.145/Vystupy/