Publication result detail

Correction of the supersonic flow impact on the results of the inserted temperature probe in the differentially pumped chamber.

ŠABACKÁ, P.; MAXA, J.; VYROUBAL, P.

Original Title

Correction of the supersonic flow impact on the results of the inserted temperature probe in the differentially pumped chamber.

English Title

Correction of the supersonic flow impact on the results of the inserted temperature probe in the differentially pumped chamber.

Type

Paper in proceedings (conference paper)

Original Abstract

This article deals with the experimental chamber preparation, on which stagnation and static temperature (besides others) will be measured. The results obtained from measurement will be compared with the results from mathematical – physics analysis of Ansys Fluent system and in this system, the temperature running and expected ratios for planned experimental measuring also will be mapped in the supersonic flow in the experimental chambers.

English abstract

This article deals with the experimental chamber preparation, on which stagnation and static temperature (besides others) will be measured. The results obtained from measurement will be compared with the results from mathematical – physics analysis of Ansys Fluent system and in this system, the temperature running and expected ratios for planned experimental measuring also will be mapped in the supersonic flow in the experimental chambers.

Keywords

Ansys, temperature probe, Differentialy pumped chamber.

Key words in English

Ansys, temperature probe, Differentialy pumped chamber.

Authors

ŠABACKÁ, P.; MAXA, J.; VYROUBAL, P.

RIV year

2020

Released

17.10.2019

Publisher

The Electrochemical Society

Location

USA

ISBN

9781607688877

Book

ABAF 20th issue of ECS Transactions

ISBN

1938-6737

Periodical

ECS Transaction

Volume

95

Number

1

State

United States of America

Pages from

491

Pages to

496

Pages count

6

URL

BibTex

@inproceedings{BUT159308,
  author="Pavla {Šabacká} and Jiří {Maxa} and Petr {Vyroubal}",
  title="Correction of the supersonic flow impact on the results of the inserted temperature probe in the differentially pumped chamber.",
  booktitle="ABAF 20th issue of ECS Transactions",
  year="2019",
  journal="ECS Transaction",
  volume="95",
  number="1",
  pages="491--496",
  publisher="The Electrochemical Society",
  address="USA",
  doi="10.1149/09501.0491ecst",
  isbn="9781607688877",
  issn="1938-6737",
  url="https://ur.booksc.eu/book/79701503/233132"
}