Original Abstract
This article has task to inform a reader calibration procedure of an integrating sphere with spectroradiometer as detector with traceability to goniophotometer and double monochromator. In the first part there is a description of each step of calibration including preparations for necessary measurement and equipment. In the second part there is a description of practical calibration in light laboratory at Brno University of Technology with results and recommendations. Last part concludes results of calibration along with uncertainty budget evaluation.
English abstract
Keywords
integrating sphere; spectroradiometer; luminous flux; goniophotometr; light standard; uncertainty of measurement
Key words in English
Authors
RIV year
2019
Released
16.05.2018
ISBN
978-1-5386-4612-0
Book
Proccedings of the 2018 19th International Scientific Conference on Electric Power Engineering (EPE)
Pages from
486
Pages to
490
Pages count
5
BibTex
@inproceedings{BUT148630, author="Martin {Motyčka} and Jan {Škoda} and Jaroslav {Štěpánek}", title="The Calibration of Integrating Sphere with spectroradiometer with Traceability to Goniophotometer", booktitle="Proccedings of the 2018 19th International Scientific Conference on Electric Power Engineering (EPE)", year="2018", number="1", pages="486--490", doi="10.1109/EPE.2018.8395971", isbn="978-1-5386-4612-0" }