Publication result detail

Earth-Fill Dam Monitored by EIS Method during Application of Nutrient Aqueous Solution used in BioSealing Method

PAŘÍLKOVÁ, J.; GJUNSBURGS, B.; ZACHOVAL, Z.; VESELÝ, J.; MŰNSTEROVÁ, Z.

Original Title

Earth-Fill Dam Monitored by EIS Method during Application of Nutrient Aqueous Solution used in BioSealing Method

English Title

Earth-Fill Dam Monitored by EIS Method during Application of Nutrient Aqueous Solution used in BioSealing Method

Type

Paper in proceedings (conference paper)

Original Abstract

The paper gives short information about the results of monitoring the electrical properties of an earth-fill dam during the application of a nutrient aqueous solution used in the method BioSealing. Monitoring is carried out using a Z-meter device when applying the method of electrical impedance spectrometry and, in some cases, is part of a system of monitoring seepage through the earth-fill dam of the water reservoir by its administrator. Information about the changes that take place in the body of the dam during the movement of the water level in the reservoir or after the influence of weather changes or human activity are given through the monitored changes in the electrical parameters of the soil of the dam with time.

English abstract

The paper gives short information about the results of monitoring the electrical properties of an earth-fill dam during the application of a nutrient aqueous solution used in the method BioSealing. Monitoring is carried out using a Z-meter device when applying the method of electrical impedance spectrometry and, in some cases, is part of a system of monitoring seepage through the earth-fill dam of the water reservoir by its administrator. Information about the changes that take place in the body of the dam during the movement of the water level in the reservoir or after the influence of weather changes or human activity are given through the monitored changes in the electrical parameters of the soil of the dam with time.

Keywords

seepage, dam, BioSealing, electrical impedance measurement, Z-meter device, continuous measurement

Key words in English

seepage, dam, BioSealing, electrical impedance measurement, Z-meter device, continuous measurement

Authors

PAŘÍLKOVÁ, J.; GJUNSBURGS, B.; ZACHOVAL, Z.; VESELÝ, J.; MŰNSTEROVÁ, Z.

RIV year

2018

Released

25.10.2017

Publisher

IOP Publishing

Location

Riga, LV

Book

3rd International Conference on Innovative Materials, Structures and Technologies (IMST 2017)

ISBN

1757-8981

Periodical

IOP Conference Series: Materials Science and Engineering

Volume

251

Number

1

State

United Kingdom of Great Britain and Northern Ireland

Pages from

1

Pages to

8

Pages count

8

URL

Full text in the Digital Library

BibTex

@inproceedings{BUT144694,
  author="Jana {Pařílková} and Boriss {Gjunsburgs} and Zbyněk {Zachoval} and Jaroslav {Veselý} and Zuzana {Műnsterová}",
  title="Earth-Fill Dam Monitored by EIS Method during Application of Nutrient Aqueous Solution used in BioSealing Method",
  booktitle="3rd International Conference on Innovative Materials, Structures and Technologies (IMST 2017)",
  year="2017",
  journal="IOP Conference Series: Materials Science and Engineering",
  volume="251",
  number="1",
  pages="1--8",
  publisher="IOP Publishing",
  address="Riga, LV",
  doi="10.1088/1757-899X/251/1/012130",
  issn="1757-8981",
  url="http://iopscience.iop.org/article/10.1088/1757-899X/251/1/012130"
}

Documents