HIMR, D.; HABÁN, V.; DOKOUPIL, P.
Original Title
Check valve slam analysis in pumping station
English Title
Type
Paper in proceedings (conference paper)
Original Abstract
Pumping station supplies water for technological process. The check valve in the station was replaced with a new one. The regular test of black out discovered the high pressure pulsations accompanied with noticeable pipeline movement of discharge pipe. It was caused by late check valve closing, probably, when the back flow reached the highest possible velocity. This statement was supported with analysis of results of pressure measurement near the check valve and with a numerical simulation of the flow in the pipeline system.
English abstract
Keywords
water hammer, check valve
Key words in English
Authors
RIV year
2017
Released
28.03.2016
Publisher
EDP Sciences
Book
EPJ Web of Conferences
ISBN
2100-014X
Periodical
Volume
114
Number
2016
State
French Republic
Pages from
1
Pages to
6
Pages count
URL
http://www.epj-conferences.org/articles/epjconf/abs/2016/09/epjconf_efm2016_02038/epjconf_efm2016_02038.html
Full text in the Digital Library
http://hdl.handle.net/11012/84112
BibTex
@inproceedings{BUT123443, author="Daniel {Himr} and Vladimír {Habán} and Pavel {Dokoupil}", title="Check valve slam analysis in pumping station", booktitle="EPJ Web of Conferences", year="2016", journal="EPJ Web of Conferences", volume="114", number="2016", pages="1--6", publisher="EDP Sciences", doi="10.1051/epjconf/201611402038", issn="2100-014X", url="http://www.epj-conferences.org/articles/epjconf/abs/2016/09/epjconf_efm2016_02038/epjconf_efm2016_02038.html" }
Documents
epjconf_efm2016_02038