ZAHÁLKA, J.; TŮMA, J.; BRADÁČ, F.
Original Title
Determination and Improvement of Performance Level of Safety Function of Emergency Stop for Machinery
English Title
Type
Paper in proceedings (conference paper)
Original Abstract
This article focuses on the calculation of performance level (PL) by standard ISO 13849-1 Safety of machinery – Safety-related parts of control systems – Part 1: General principles for design [1]. Requirements of current standards are discussed and a typical composition of emergency stop is presented. Safety parameters of components and their determination and calculation are shown. The steps to determine the performance level for safety function of emergency stop along with a proposal to improve the reliability of existing systems are outlined.
English abstract
Keywords
Performance Level; safety function; reliability; backup
Key words in English
Authors
RIV year
2017
Released
25.03.2014
Publisher
Elsevier
Location
Zadar
ISBN
978-3-901509-97-1
Book
Annals of DAAAM International 2013
Edition
24
1877-7058
Periodical
Procedia Engineering
Volume
69
Number
1
State
United Kingdom of Great Britain and Northern Ireland
Pages from
1242
Pages to
1250
Pages count
9
URL
https://www.sciencedirect.com/science/article/pii/S1877705814003610
Full text in the Digital Library
http://hdl.handle.net/11012/194736
BibTex
@inproceedings{BUT106442, author="Jiří {Zahálka} and Jiří {Tůma} and František {Bradáč}", title="Determination and Improvement of Performance Level of Safety Function of Emergency Stop for Machinery", booktitle="Annals of DAAAM International 2013", year="2014", series="24", journal="Procedia Engineering", volume="69", number="1", pages="1242--1250", publisher="Elsevier", address="Zadar", doi="10.1016/j.proeng.2014.03.115", isbn="978-3-901509-97-1", url="https://www.sciencedirect.com/science/article/pii/S1877705814003610" }
Documents
1-s2.0-S1877705814003610-main