Project detail

Measurement and ageing of battery materials

Duration: 25.05.2011 — 16.11.2011

Funding resources

Neveřejný sektor - Přímé kontrakty - smluvní výzkum, neveřejné zdroje
- whole funder (2011-09-09 - 2011-11-16)

On the project

The project contains the measurements of discharge characteristics of nickel electrodes which contain 20% of graphite samples labelled S1, S3, S4, S8, S10, S11, S12, S13 and S14 from company Graphit kropfműhl AG. Electrodes were prepared with the Ni(OH)2 and these were measured in cells by galvanostatic cycling. The measurements were repeated after 10-days ageing at 40°C and at constant voltage 1.3 V. Commercial cadmium material labelled Kans G was used as negative electrode.

Description in Czech
Projek obsahuje měření vybíjecích charakteristik niklových elektrod s 20% přídavkem grafitu s označením S1, S3, S4, S8, S10, S11, S12, S13 a S14 od firmy Graphite kropfműhl AG. Elektrody byly připraveny s Ni(OH)2 od firmy Bochemie a měřeny metodou galvanostatického cyklování. Měření bylo opakováno s periodou 10 dní, během kterých byly vzorky připojeny na napětí 1,3 V a byly stárnuty při teplotě 40°C. Komerční hmota Kans G byla použita pro zápornou elektrodu.

Keywords
accumulator, graphite, carbon, nickel, cadmium

Key words in Czech
akumulátor, grafit, uhlík, nikl, kadmium

Mark

Graphit kropfmuhl -Chladil

Default language

English

People responsible

Chladil Ladislav, Ing., Ph.D. - principal person responsible

Units

Results

CHLADIL, L. Corrosion measurement of carbon materials in the battery application - 3rd research report. 2011.
Detail