The m-sequence cross-correlation method is a powerful approach for obtaining a linear system impulse response estimate. However, when the system under test exhibits non-linear behaviour, the obtained estimate contains some artefacts, which are not part of the linear system impulse response. This paper describes the origin of these artefacts and how they arise.

English abstract

The m-sequence cross-correlation method is a powerful approach for obtaining a linear system impulse response estimate. However, when the system under test exhibits non-linear behaviour, the obtained estimate contains some artefacts, which are not part of the linear system impulse response. This paper describes the origin of these artefacts and how they arise.

Keywords

m-sequence cross-correlation, non-linearities

Key words in English

m-sequence cross-correlation, non-linearities

Authors

VYCHODIL, J.

RIV year

2017

Released

29.08.2016

Publisher

Vysoké učení technické

Location

Brno

ISBN

978-80-214-5389-0

Book

Sborník příspěvků studentské konference Blansko 2016

Pages from

98

Pages to

101

Pages count

3

BibTex

@inproceedings{BUT127622,
  author="Josef {Vychodil}",
  title="System Impulse Response Measurement Using M-sequences in the Presence of Non-linearities",
  booktitle="Sborník příspěvků studentské konference Blansko 2016",
  year="2016",
  pages="98--101",
  publisher="Vysoké učení technické",
  address="Brno",
  isbn="978-80-214-5389-0"
}