Detail publikace
INPUT CONTROL OF SENSOR PARAMETERS AND REPRODUCIBILITY OF SENSOR MEASUREMENT
FUJCIK, L., VRBA, R., KREJČÍ, J., HÁZE, J., SKOČDOPOLE, M., SAJDL, O.
Originální název
INPUT CONTROL OF SENSOR PARAMETERS AND REPRODUCIBILITY OF SENSOR MEASUREMENT
Anglický název
INPUT CONTROL OF SENSOR PARAMETERS AND REPRODUCIBILITY OF SENSOR MEASUREMENT
Jazyk
en
Originální abstrakt
Fast detection of pesticide toxicity in the field conditions is very important in many aspects (longtime influence of low concentrations on man´s health, pesticide storage, price of one test etc.). The pesticide concentration measurements are performed on a biosensor with acetylcholinesterase (AChE). The AChE is a very sensitive compound. The measurement uses principle of an artificial synapse (AS) and inhibition of an enzyme Acetylcholinesterase (AChE). The AS is a very effective detector of the pesticide toxicity. Therefore properties of the sensor have to be measured without AChE at first. This process is called input control of the sensor. The reproducibility of electrochemical detector is studied first using hydrogen peroxide and second ferri-ferrokyanide redox couple. The parameters of electrochemical detector itself were evaluated statistically.
Anglický abstrakt
Fast detection of pesticide toxicity in the field conditions is very important in many aspects (longtime influence of low concentrations on man´s health, pesticide storage, price of one test etc.). The pesticide concentration measurements are performed on a biosensor with acetylcholinesterase (AChE). The AChE is a very sensitive compound. The measurement uses principle of an artificial synapse (AS) and inhibition of an enzyme Acetylcholinesterase (AChE). The AS is a very effective detector of the pesticide toxicity. Therefore properties of the sensor have to be measured without AChE at first. This process is called input control of the sensor. The reproducibility of electrochemical detector is studied first using hydrogen peroxide and second ferri-ferrokyanide redox couple. The parameters of electrochemical detector itself were evaluated statistically.
Dokumenty
BibTex
@inproceedings{BUT7539,
author="Lukáš {Fujcik} and Radimír {Vrba} and Jan {Krejčí} and Jiří {Háze} and Michal {Skočdopole} and Ondřej {Sajdl}",
title="INPUT CONTROL OF SENSOR PARAMETERS AND REPRODUCIBILITY OF SENSOR MEASUREMENT",
annote="Fast detection of pesticide toxicity in the field conditions is very important in many aspects (longtime influence of low concentrations on man´s health, pesticide storage, price of one test etc.). The pesticide concentration measurements are performed on a biosensor with acetylcholinesterase (AChE). The AChE is a very sensitive compound. The measurement uses principle of an artificial synapse (AS) and inhibition of an enzyme Acetylcholinesterase (AChE). The AS is a very effective detector of the pesticide toxicity. Therefore properties of the sensor have to be measured without AChE at first. This process is called input control of the sensor. The reproducibility of electrochemical detector is studied first using hydrogen peroxide and second ferri-ferrokyanide redox couple. The parameters of electrochemical detector itself were evaluated statistically.",
booktitle="XVII IMEKO WORLD CONGRESS",
chapter="7539",
year="2003",
month="january",
pages="2141",
type="conference paper"
}